Eco-friendly electrochemical assay of oxytetracycline and flunixin in their veterinary injections and spiked milk samples

Two solid-contact electrochemical sensors were developed for detection of each of oxytetracycline HCl (OXY), and the co-formulated non-steroidal anti-inflammatory drug flunixin meglumine (FLU) in veterinary formulations and animal-derived food products. The designed sensors were based on a glassy carbon electrode as the substrate material and high molecular weight polyvinyl chloride (PVC) polymeric ion-sensing membranes doped with multiwalled carbon nanotubes (MWCNTs) to improve the potential stability and minimize signal drift. For determination of OXY, the sensing membrane was modified with potassium tetrakis (4-chlorophenyl) borate (K-TCPB), which was employed as a cation exchanger, and 2-hydroxypropyl-β-cyclodextrin (HP-ßCD), which was used as an ionophore. A linear response within a concentration range of 1 × 10<sup>- 6</sup>-1 × 10<sup>- 2</sup> M with a slope of 59.47 mV/decade over a pH range of 1-5 was recorded. For the first time, two potentiometric electrodes were developed for determination of FLU, where the sensing membrane was modified with tetra dodecyl ammonium chloride (TDDAC) as an anion exchanger. A linear response within a concentration range of 1 × 10<sup>- 5</sup>-1 × 10<sup>- 2</sup> M and a slope of -58.21 mV/decade over a pH range of 6-11 was observed. The suggested sensors were utilized for the selective determination of each drug in pure powder form, in veterinary formulations, and in spiked milk samples, with mean recoveries ranging from 98.50 to 102.10, and without any observed interference. The results acquired by the proposed sensors were statistically analyzed and compared with those acquired by the official methods, and the results showed no significant difference.

Authors

Institutions

Publication Details

Journal
BMC Chemistry
Published
2024-09-19
DOI
https://doi.org/10.1186/s13065-024-01282-4
Citations
4
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Eco-friendly electrochemical assay of oxytetracycline and flunixin in their veterinary injections and spiked milk samples

Yossra A. Trabik, Hind A Abdullatif, Adel M. Michael, Amr M. Mahmoud et al.
4 citations
BMC Chemistry
Analytical Chemistry and Sensors
1.16
article

Eco-friendly electrochemical assay of oxytetracycline and flunixin in their veterinary injections and spiked milk samples

Yossra A. Trabik, Hind A Abdullatif, Adel M. Michael, Amr M. Mahmoud, Miriam F. Ayad
article en
4 citations

Abstract

Two solid-contact electrochemical sensors were developed for detection of each of oxytetracycline HCl (OXY), and the co-formulated non-steroidal anti-inflammatory drug flunixin meglumine (FLU) in veterinary formulations and animal-derived food products. The designed sensors were based on a glassy carbon electrode as the substrate material and high molecular weight polyvinyl chloride (PVC) polymeric ion-sensing membranes doped with multiwalled carbon nanotubes (MWCNTs) to improve the potential stability and minimize signal drift. For determination of OXY, the sensing membrane was modified with potassium tetrakis (4-chlorophenyl) borate (K-TCPB), which was employed as a cation exchanger, and 2-hydroxypropyl-β-cyclodextrin (HP-ßCD), which was used as an ionophore. A linear response within a concentration range of 1 × 10<sup>- 6</sup>-1 × 10<sup>- 2</sup> M with a slope of 59.47 mV/decade over a pH range of 1-5 was recorded. For the first time, two potentiometric electrodes were developed for determination of FLU, where the sensing membrane was modified with tetra dodecyl ammonium chloride (TDDAC) as an anion exchanger. A linear response within a concentration range of 1 × 10<sup>- 5</sup>-1 × 10<sup>- 2</sup> M and a slope of -58.21 mV/decade over a pH range of 6-11 was observed. The suggested sensors were utilized for the selective determination of each drug in pure powder form, in veterinary formulations, and in spiked milk samples, with mean recoveries ranging from 98.50 to 102.10, and without any observed interference. The results acquired by the proposed sensors were statistically analyzed and compared with those acquired by the official methods, and the results showed no significant difference.

BMC ChemistryVol. 18(1)
Ain Shams University (EG), Cairo University (EG), Ahram Canadian University (EG)
Ain Shams University, Cairo University, Science and Technology Development Fund
Responsible consumption and production
Openalex Percentile: Top 25%
Analytical Chemistry and Sensors
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.