Evaluation of a Three-Dimensional Printed Interventional Simulator for Cardiac Ablation Therapy Training

Cardiac ablation (CA) is an interventional electrophysiological procedure used to disrupt arrhythmic substrates in the myocardium by inducing localized scarring. Current CA training relies on the master–apprentice model. In different fields of medicine including CA, virtual and physical simulators have proven to enhance, and even outperform, conventional training modalities while providing a risk-free learning environment. Despite the benefits, high costs and operational difficulties limit the widespread use of interventional simulators. Our previous research introduced a low-cost CA simulator using a 3D-printed biatrial cardiac model, successfully recording ten ablation lesions on the phantom myocardium. In this work, we present and evaluate an enhanced version: compared to the previous version, the cardiac phantom’s electrical behavior and ablation settings were optimized to produce consistent lesions, while 3D-printed components improved the haptic and radiographic properties of the simulator. Seven cardiologists compared the experimental simulator’s performance to the leading commercial system from Heartroid in a 24-question survey on a 5-point Likert scale. The four following areas of fidelity were considered: catheter entry, anatomical correctness, radiographic appearance, and mapping and ablation. The experimental simulator significantly outperformed the commercial system (p < 0.01), particularly in radiographic appearance (p < 0.01). The results show the potential for the experimental simulator in routine CA training.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-09-19
DOI
https://doi.org/10.3390/app14188423
Citations
4
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a Three-Dimensional Printed Interventional Simulator for Cardiac Ablation Therapy Training

Kawal Rhode, Jonathan M. Behar, Antonia Pontiki, Lisa Leung et al.
4 citations
Applied Sciences
Cardiac Arrhythmias and Treatments
1.61
article

Evaluation of a Three-Dimensional Printed Interventional Simulator for Cardiac Ablation Therapy Training

Kawal Rhode, Jonathan M. Behar, Antonia Pontiki, Lisa Leung, Pierre Berthet-Rayne, R. James Housden, Gregory A. Gibson, Carlo Saija, Sachin Sabu, Marco Pinto, Calum Byrne, Ewen Marion, Adharvan Gabbeta, Noor Al-Bahrani, Nadia M. Chowdhury, Ellie Lowe, Rashi Chavan, Mark Herridge
article en
4 citations

Abstract

Cardiac ablation (CA) is an interventional electrophysiological procedure used to disrupt arrhythmic substrates in the myocardium by inducing localized scarring. Current CA training relies on the master–apprentice model. In different fields of medicine including CA, virtual and physical simulators have proven to enhance, and even outperform, conventional training modalities while providing a risk-free learning environment. Despite the benefits, high costs and operational difficulties limit the widespread use of interventional simulators. Our previous research introduced a low-cost CA simulator using a 3D-printed biatrial cardiac model, successfully recording ten ablation lesions on the phantom myocardium. In this work, we present and evaluate an enhanced version: compared to the previous version, the cardiac phantom’s electrical behavior and ablation settings were optimized to produce consistent lesions, while 3D-printed components improved the haptic and radiographic properties of the simulator. Seven cardiologists compared the experimental simulator’s performance to the leading commercial system from Heartroid in a 24-question survey on a 5-point Likert scale. The four following areas of fidelity were considered: catheter entry, anatomical correctness, radiographic appearance, and mapping and ablation. The experimental simulator significantly outperformed the commercial system (p < 0.01), particularly in radiographic appearance (p < 0.01). The results show the potential for the experimental simulator in routine CA training.

Applied SciencesVol. 14(18)
King's College London (GB), Guy's and St Thomas' NHS Foundation Trust (GB), St George's Hospital (GB)
National Institute for Health and Care Research, British Heart Foundation, Department of Health and Social Care, King's College London, Centre For Medical Engineering, King’s College London, Biosense Webster
Openalex Percentile: Top 15%
Cardiac Arrhythmias and Treatments
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.