Development and Validation of the MAST ISOPLEX® VTEC Kit for Simultaneous Detection of Shiga Toxin/Verotoxin 1 and 2 (stx1/vt1 and stx2/vt2) with Inhibition Control (IC) in a Rapid Loop-Mediated Isothermal Amplification (LAMP) Multiplex Assay

Loop-mediated isothermal amplification (LAMP) is a cost-effective, rapid, and highly specific method of replicating nucleic acids. Adding multiple targets into a single LAMP assay to create a multiplex format is highly desirable for clinical applications but has been challenging due to a need to develop specific detection techniques and strict primer design criteria. This study describes the evaluation of a rapid triplex LAMP assay, MAST ISOPLEX<sup>®</sup><i>VTEC</i>, for the simultaneous detection of Shiga toxin/verotoxin 1 and 2 (<i>stx1/vt1</i> and <i>stx2/vt2</i>) genes in verotoxigenic <i>Escherichia coli (E. coli)</i> (<i>VTEC</i>) isolates with inhibition control (IC) synthetic DNA using a single fluorophore-oligonucleotide probe, MAST ISOPLEX<sup>®</sup><i>Probes,</i> integrated into the primer set of each target. MAST ISOPLEX<sup>®</sup><i>Probes</i> used in the MAST ISOPLEX<sup>®</sup><i>VTEC</i> kit produce fluorescent signals as they integrate with reaction products specific to each target, allowing tracking of multiple amplifications in real time using a real-time analyzer. Initial validation on DNA extracts from fecal cultures and synthetic DNA sequences (gBlocks) showed that the MAST ISOPLEX<sup>®</sup><i>VTEC</i> kit provides a method for sensitive simultaneous triplex detection in a single assay with a limit of detection (LOD) of less than 100 target copies/assay and 96% and 100% sensitivity and specificity, respectively.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2024-09-19
DOI
https://doi.org/10.3390/ijms251810067
Citations
2
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of the MAST ISOPLEX® VTEC Kit for Simultaneous Detection of Shiga Toxin/Verotoxin 1 and 2 (stx1/vt1 and stx2/vt2) with Inhibition Control (IC) in a Rapid Loop-Mediated Isothermal Amplification (LAMP) Multiplex Assay

Monika Suwara, Matthew Bennett, Ilaria Anna Pia Voto, Christopher Allan Brownlie et al.
2 citations
International Journal of Molecular Sciences
Biosensors and Analytical Detection
0.37
article

Development and Validation of the MAST ISOPLEX® VTEC Kit for Simultaneous Detection of Shiga Toxin/Verotoxin 1 and 2 (stx1/vt1 and stx2/vt2) with Inhibition Control (IC) in a Rapid Loop-Mediated Isothermal Amplification (LAMP) Multiplex Assay

Monika Suwara, Matthew Bennett, Ilaria Anna Pia Voto, Christopher Allan Brownlie, E Gillies
article en
2 citations

Abstract

Loop-mediated isothermal amplification (LAMP) is a cost-effective, rapid, and highly specific method of replicating nucleic acids. Adding multiple targets into a single LAMP assay to create a multiplex format is highly desirable for clinical applications but has been challenging due to a need to develop specific detection techniques and strict primer design criteria. This study describes the evaluation of a rapid triplex LAMP assay, MAST ISOPLEX<sup>®</sup><i>VTEC</i>, for the simultaneous detection of Shiga toxin/verotoxin 1 and 2 (<i>stx1/vt1</i> and <i>stx2/vt2</i>) genes in verotoxigenic <i>Escherichia coli (E. coli)</i> (<i>VTEC</i>) isolates with inhibition control (IC) synthetic DNA using a single fluorophore-oligonucleotide probe, MAST ISOPLEX<sup>®</sup><i>Probes,</i> integrated into the primer set of each target. MAST ISOPLEX<sup>®</sup><i>Probes</i> used in the MAST ISOPLEX<sup>®</sup><i>VTEC</i> kit produce fluorescent signals as they integrate with reaction products specific to each target, allowing tracking of multiple amplifications in real time using a real-time analyzer. Initial validation on DNA extracts from fecal cultures and synthetic DNA sequences (gBlocks) showed that the MAST ISOPLEX<sup>®</sup><i>VTEC</i> kit provides a method for sensitive simultaneous triplex detection in a single assay with a limit of detection (LOD) of less than 100 target copies/assay and 96% and 100% sensitivity and specificity, respectively.

International Journal of Molecular SciencesVol. 25(18)
MAST Carbon (United Kingdom) (GB), University of Edinburgh (GB)
Public Health England
Openalex Percentile: Top 44%
Biosensors and Analytical Detection
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.