A calibration method for a wireless real-time CMOS pixel medical dosimeter

This study introduces and validates a novel calibration function for wireless wearable dosimeters, crucial for real-time dosimetry in interventional radiology. Focusing on enhancing accuracy and safety, it compares data from threshold-based wireless dosimeters with a full-data-read detector. The research involves a central detector and four lateral wireless dosimeters, each equipped with an identically-typed CMOS Image Sensor (CIS), subjected to various photon dose rates and doses from a certified beam. Two key calibration functions were developed: one that correlates the pixel count over a threshold with the dose rate, and the other that links the cumulative pixel value above the threshold to the total absorbed dose. These functions are essential in converting raw CIS data into precise dosimetric information. The study findings reveal that the single-pixel sensitivity of wireless prototypes is approximately 8.5 ± 0.8 ADC/nGy. Following the application of calibration functions, the responses of these prototypes align consistently with the TLD dosimeter measurements. In particular, for three of the prototypes, this calibration ensures that the measurement uncertainty remains within 6% for the dose rate and within 8% for the dose. This research confirms the effectiveness and feasibility of pixel-based wireless dosimeters in interventional radiology, highlighting the importance of integrating offline data processing for enhanced measurement precision. • Novel calibration for real-time CMOS pixel dosimeters improves accuracy. • Study validates wireless dosimeter against traditional TLD for precision. • Enhanced safety in interventional radiology with instant dosimetry feedback.

Authors

Institutions

Publication Details

Journal
Radiation Physics and Chemistry
Published
2024-09-19
DOI
https://doi.org/10.1016/j.radphyschem.2024.112242
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A calibration method for a wireless real-time CMOS pixel medical dosimeter

L. Servoli, K. Kanxheri, L. Fanò, Sofia Ceccarelli et al.
Radiation Physics and Chemistry
Advanced Radiotherapy Techniques
article

A calibration method for a wireless real-time CMOS pixel medical dosimeter

L. Servoli, K. Kanxheri, L. Fanò, Sofia Ceccarelli, P. Placidi, M. Pennicchi
article en

Abstract

This study introduces and validates a novel calibration function for wireless wearable dosimeters, crucial for real-time dosimetry in interventional radiology. Focusing on enhancing accuracy and safety, it compares data from threshold-based wireless dosimeters with a full-data-read detector. The research involves a central detector and four lateral wireless dosimeters, each equipped with an identically-typed CMOS Image Sensor (CIS), subjected to various photon dose rates and doses from a certified beam. Two key calibration functions were developed: one that correlates the pixel count over a threshold with the dose rate, and the other that links the cumulative pixel value above the threshold to the total absorbed dose. These functions are essential in converting raw CIS data into precise dosimetric information. The study findings reveal that the single-pixel sensitivity of wireless prototypes is approximately 8.5 ± 0.8 ADC/nGy. Following the application of calibration functions, the responses of these prototypes align consistently with the TLD dosimeter measurements. In particular, for three of the prototypes, this calibration ensures that the measurement uncertainty remains within 6% for the dose rate and within 8% for the dose. This research confirms the effectiveness and feasibility of pixel-based wireless dosimeters in interventional radiology, highlighting the importance of integrating offline data processing for enhanced measurement precision. • Novel calibration for real-time CMOS pixel dosimeters improves accuracy. • Study validates wireless dosimeter against traditional TLD for precision. • Enhanced safety in interventional radiology with instant dosimetry feedback.

Radiation Physics and ChemistryVol. 226
University of Perugia (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Perugia (IT)
Affordable and clean energy
Openalex Percentile: Top 79%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.