Designs and mechanical responses of 3D-printed Ti6Al4V porous structures based on triply periodic minimal surfaces with different iso-values

With the increasing applications of additive manufacturing in orthopaedic implants and numerous designs of porous structures available, there is a strong need and opportunity to optimize the structure designs for improved bone integration. Here we created a unique group of sheet structures based on triply periodic minimal surface (TPMS) by varying the iso-value and systematically examined how iso-value influences the mechanical performance of sheet diamond TPMS structures compared to the Octet truss structure. Four iso-values (C) 0, 0.25, 0.5, and 0.75 were designed for sheet Diamond (OSD) TPMS with varying porosity, and Ti6Al4V powder bed fusion was used to produce the porous structures. Compressive tests revealed that iso-value C significantly affected mechanical performance, and interestingly, the impact was porosity-dependent. At high relative density (>0.25), OSD0 (C = 0) displayed the highest elastic modulus and yield strength, whereas at low relative density (<0.25), OSD0.5 showed the highest among all OSD structures. Regarding failure mechanisms, OSD0, OSD0.25, and OSD0.75 showed a mixed domination of stretching and bending, while OSD0.5 was predominantly stretching-dominated. Finite Element Analysis (FEA) found that local yielding initiated at cell nodes upon loading, followed by surface bending and the formation of single or multiple shear bands near the cell nodes. This work demonstrated the feasibility of improving the mechanical performance of porous TPMS structures by simple adjustments in their governing trigonometric functions, serving as a starting point to customize porous structures for specific applications.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2024-09-19
DOI
https://doi.org/10.1016/j.jmbbm.2024.106752
Citations
9
Primary Topic
Cellular and Composite Structures
Type
article
Field-Weighted Citation Impact
1.91

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Designs and mechanical responses of 3D-printed Ti6Al4V porous structures based on triply periodic minimal surfaces with different iso-values

Rizhi Wang, Dekun Zhang, Xin Zhang
9 citations
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Cellular and Composite Structures
1.91
article

Designs and mechanical responses of 3D-printed Ti6Al4V porous structures based on triply periodic minimal surfaces with different iso-values

Rizhi Wang, Dekun Zhang, Xin Zhang
article en
9 citations

Abstract

With the increasing applications of additive manufacturing in orthopaedic implants and numerous designs of porous structures available, there is a strong need and opportunity to optimize the structure designs for improved bone integration. Here we created a unique group of sheet structures based on triply periodic minimal surface (TPMS) by varying the iso-value and systematically examined how iso-value influences the mechanical performance of sheet diamond TPMS structures compared to the Octet truss structure. Four iso-values (C) 0, 0.25, 0.5, and 0.75 were designed for sheet Diamond (OSD) TPMS with varying porosity, and Ti6Al4V powder bed fusion was used to produce the porous structures. Compressive tests revealed that iso-value C significantly affected mechanical performance, and interestingly, the impact was porosity-dependent. At high relative density (>0.25), OSD0 (C = 0) displayed the highest elastic modulus and yield strength, whereas at low relative density (<0.25), OSD0.5 showed the highest among all OSD structures. Regarding failure mechanisms, OSD0, OSD0.25, and OSD0.75 showed a mixed domination of stretching and bending, while OSD0.5 was predominantly stretching-dominated. Finite Element Analysis (FEA) found that local yielding initiated at cell nodes upon loading, followed by surface bending and the formation of single or multiple shear bands near the cell nodes. This work demonstrated the feasibility of improving the mechanical performance of porous TPMS structures by simple adjustments in their governing trigonometric functions, serving as a starting point to customize porous structures for specific applications.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 160
University of British Columbia (CA), China University of Mining and Technology (CN)
China Scholarship Council, University of British Columbia, Natural Sciences and Engineering Research Council of Canada
Sustainable cities and communities
Openalex Percentile: Top 15%
Cellular and Composite Structures
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.