The Effects of Abnormal Exposure on Individual Dose Monitoring with TLD Dosimeters

Objectives: To analyze the effects of normal x-ray inspection, machine washing, and machine drying on thermoluminescent dosimeter (TLD) measurements during external individual monitoring and to provide suggestions for determining individual monitoring measurements under the mentioned abnormal situations. In this study, we focused on three abnormal situations: x-ray inspection, machine washing, and machine drying, which are common in external individual dose monitoring. We measured and compared the doses from TLD with and without 11, 23, 35, and 50 security checks. We used different radiation sources to expose the TLDs before or after machine washing with or without hot drying. The three radiation sources are natural background radiation, 137 Cs γ rays, and 320 kVp x-rays. We measured 20 TLDs for each situation. The average doses for the TLDs with 11, 23, 35, 50 security checks are 27.7 μGy, 59.7 μGy, 84.1 μGy, and 121.0 μGy, respectively. We measured an average dose of 2.5 μGy per exposure. The doses showed no significant difference between different times of washing with different radiation sources, natural background radiation, 137 Cs, or x-ray exposures. There was also no significant difference between the dose coming from the controlled group, drying at 60 °C and 90 °C for 1 h after exposure to 137 Cs γ rays and 320 kVp x-rays. The common machine drying under the temperature of 90 °C did not affect TLD measured doses.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2024-09-19
DOI
https://doi.org/10.1097/hp.0000000000001874
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effects of Abnormal Exposure on Individual Dose Monitoring with TLD Dosimeters

Michael G. Stabin, Yanling Yi
1 citations
Health Physics
Radiation Dose and Imaging
0.40
article

The Effects of Abnormal Exposure on Individual Dose Monitoring with TLD Dosimeters

Michael G. Stabin, Yanling Yi
article en
1 citations

Abstract

Objectives: To analyze the effects of normal x-ray inspection, machine washing, and machine drying on thermoluminescent dosimeter (TLD) measurements during external individual monitoring and to provide suggestions for determining individual monitoring measurements under the mentioned abnormal situations. In this study, we focused on three abnormal situations: x-ray inspection, machine washing, and machine drying, which are common in external individual dose monitoring. We measured and compared the doses from TLD with and without 11, 23, 35, and 50 security checks. We used different radiation sources to expose the TLDs before or after machine washing with or without hot drying. The three radiation sources are natural background radiation, 137 Cs γ rays, and 320 kVp x-rays. We measured 20 TLDs for each situation. The average doses for the TLDs with 11, 23, 35, 50 security checks are 27.7 μGy, 59.7 μGy, 84.1 μGy, and 121.0 μGy, respectively. We measured an average dose of 2.5 μGy per exposure. The doses showed no significant difference between different times of washing with different radiation sources, natural background radiation, 137 Cs, or x-ray exposures. There was also no significant difference between the dose coming from the controlled group, drying at 60 °C and 90 °C for 1 h after exposure to 137 Cs γ rays and 320 kVp x-rays. The common machine drying under the temperature of 90 °C did not affect TLD measured doses.

Health PhysicsVol. 127(6)
Fudan University (CN)
Openalex Percentile: Top 35%
Radiation Dose and Imaging
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.