Research on signal denoising algorithm based on ICEEMDAN eddy current detection

Abstract This study addresses the challenges of non-stationarity and significant background noise interference in eddy current detection signals by proposing a noise reduction method based on Improved Complete Ensemble Empirical Mode Decomposition with Adapted Noise (ICEEMDAN). The process commences with the signal being decomposed using Improved Complete Ensemble Empirical Mode Decomposition with Adapted Noise into a finite number of Intrinsic Mode Functions (IMFs). Each Intrinsic Mode Function is then evaluated for the presence of high-frequency noise using a Power Spectral Density (PSD) analysis. The high-frequency noise present in the Intrinsic Mode Functions is then reduced using Normalized Least Mean Squares (NLMS) before being reconstructed with the remaining Intrinsic Mode Functions. Subsequently, the reconstructed signals are subjected to another round of decomposition using Improved Complete Ensemble Empirical Mode Decomposition with Adapted Noise. The Pearson Product Moment Correlation Coefficient (PPMCC) is utilised to calculate the correlation between the Intrinsic Mode Functions within each layer, retaining those with a strong correlation to further attenuate noise. Ultimately, the local maxima judgement method selectively amplifies defect signals by assessing changes in peak and valley degrees, thereby improving the signal-to-noise ratio of the eddy current detection signal. The experimental results demonstrate that, in comparison to the use of only the conventional Improved Complete Ensemble Empirical Mode Decomposition with Adapted Noise and Normalized Least Mean Squares denoising methods, the proposed method increases the Signal-to-Noise Ratio (SNR) by 1.08 dB and 2.31 dB, respectively, and decreases the Mean Square Error (MSE) by 106.9 and 223.9, respectively. The false alarm rate for stainless steel welded tubes with defects is 1.4%, while the false alarm rate for stainless steel welded tubes without defects is 0.4%.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-09-01
DOI
https://doi.org/10.1088/1748-0221/19/09/p09026
Citations
4
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
1.31
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on signal denoising algorithm based on ICEEMDAN eddy current detection

Zhifan Zhao, Huaishu Hou, Jinhao Li, Shuaijun Xia et al.
4 citations
Journal of Instrumentation
Machine Fault Diagnosis Techniques
1.31
article

Research on signal denoising algorithm based on ICEEMDAN eddy current detection

Zhifan Zhao, Huaishu Hou, Jinhao Li, Shuaijun Xia, Qi Liu
article en
4 citations

Abstract

Abstract This study addresses the challenges of non-stationarity and significant background noise interference in eddy current detection signals by proposing a noise reduction method based on Improved Complete Ensemble Empirical Mode Decomposition with Adapted Noise (ICEEMDAN). The process commences with the signal being decomposed using Improved Complete Ensemble Empirical Mode Decomposition with Adapted Noise into a finite number of Intrinsic Mode Functions (IMFs). Each Intrinsic Mode Function is then evaluated for the presence of high-frequency noise using a Power Spectral Density (PSD) analysis. The high-frequency noise present in the Intrinsic Mode Functions is then reduced using Normalized Least Mean Squares (NLMS) before being reconstructed with the remaining Intrinsic Mode Functions. Subsequently, the reconstructed signals are subjected to another round of decomposition using Improved Complete Ensemble Empirical Mode Decomposition with Adapted Noise. The Pearson Product Moment Correlation Coefficient (PPMCC) is utilised to calculate the correlation between the Intrinsic Mode Functions within each layer, retaining those with a strong correlation to further attenuate noise. Ultimately, the local maxima judgement method selectively amplifies defect signals by assessing changes in peak and valley degrees, thereby improving the signal-to-noise ratio of the eddy current detection signal. The experimental results demonstrate that, in comparison to the use of only the conventional Improved Complete Ensemble Empirical Mode Decomposition with Adapted Noise and Normalized Least Mean Squares denoising methods, the proposed method increases the Signal-to-Noise Ratio (SNR) by 1.08 dB and 2.31 dB, respectively, and decreases the Mean Square Error (MSE) by 106.9 and 223.9, respectively. The false alarm rate for stainless steel welded tubes with defects is 1.4%, while the false alarm rate for stainless steel welded tubes without defects is 0.4%.

Journal of InstrumentationVol. 19(09)
Shanghai Institute of Technology (CN)
Openalex Percentile: Top 19%
Machine Fault Diagnosis Techniques
1.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.