Three-Dimensional Nanoscale Imaging of SiO2 Nanofiller in Styrene-Butadiene Rubber with High-Resolution and High-Sensitivity Ptychographic X-ray Computed Tomography

SiO2 aggregates in styrene-butadiene rubber (SBR) were observed using ptychographic X-ray computed tomography (PXCT). The rubber composites were illuminated with X-rays focused by total reflection focusing mirrors, and the ptychographic diffraction patterns were collected using a CITIUS detector in the range of -75° to +75° angle of incidence. The projection images of the rubber composites were reconstructed with a two-dimensional resolution of 76 nm, and no significant structural changes were observed during the PXCT measurements. A three-dimensional image of the rubber composite was reconstructed with an isotropic resolution of 98 nm. Segmentation of SiO2 from the SBR, based on a histogram analysis of the phase shift, revealed a fragmented network structure of interconnected SiO2 aggregates.

Authors

Institutions

Publication Details

Journal
Microscopy and Microanalysis
Published
2024-09-19
DOI
https://doi.org/10.1093/mam/ozae094
Citations
4
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
2.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-Dimensional Nanoscale Imaging of SiO2 Nanofiller in Styrene-Butadiene Rubber with High-Resolution and High-Sensitivity Ptychographic X-ray Computed Tomography

Yasumasa Joti, Hideshi Uematsu, Yoshiaki Honjo, Shuntaro Takazawa et al.
4 citations
Microscopy and Microanalysis
Advanced X-ray Imaging Techniques
2.43
article

Three-Dimensional Nanoscale Imaging of SiO2 Nanofiller in Styrene-Butadiene Rubber with High-Resolution and High-Sensitivity Ptychographic X-ray Computed Tomography

Yasumasa Joti, Hideshi Uematsu, Yoshiaki Honjo, Shuntaro Takazawa, Kyosuke Ozaki, Takaki Hatsui, Nozomu Ishiguro, H. Nishino, Yukio Takahashi, Masaki Abe, Yuhei Sasaki, Naru Okawa
article en
4 citations

Abstract

SiO2 aggregates in styrene-butadiene rubber (SBR) were observed using ptychographic X-ray computed tomography (PXCT). The rubber composites were illuminated with X-rays focused by total reflection focusing mirrors, and the ptychographic diffraction patterns were collected using a CITIUS detector in the range of -75° to +75° angle of incidence. The projection images of the rubber composites were reconstructed with a two-dimensional resolution of 76 nm, and no significant structural changes were observed during the PXCT measurements. A three-dimensional image of the rubber composite was reconstructed with an isotropic resolution of 98 nm. Segmentation of SiO2 from the SBR, based on a histogram analysis of the phase shift, revealed a fragmented network structure of interconnected SiO2 aggregates.

Microscopy and MicroanalysisVol. 30(5)
Tohoku University (JP), SPring-8 (JP), Japan Synchrotron Radiation Research Institute (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 12%
Advanced X-ray Imaging Techniques
2.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.