Proposal of BESOI MOSFET source sensing region for pH monitoring applications

This work presents a study of the sensing regions of <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">BE</sup>SOI MOSFET for pH sensing using TCAD Sentaurus simulation. A new approach was used to model the electrolyte, based on the literature, as the simulator previously lacked a model for this type of material. The simulation results show an increase in drain current levels for acidic pH values and a decrease for basic pH values. Additionally, the drain voltage demonstrates an influence on the electrolyte charges, which worsens the device sensitivity. Therefore, a new device was proposed, using only the source sensing region to avoid drain influence. This new device shows an improvement in sensitivity and optimizes the obtained results for future experimental analyses.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/sbmicro64348.2024.10673858
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proposal of BESOI MOSFET source sensing region for pH monitoring applications

Ricardo C. Rangel, Pedro Henrique Duarte, João Antônio Martino
Analytical Chemistry and Sensors
article

Proposal of BESOI MOSFET source sensing region for pH monitoring applications

Ricardo C. Rangel, Pedro Henrique Duarte, João Antônio Martino
article en

Abstract

This work presents a study of the sensing regions of <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">BE</sup>SOI MOSFET for pH sensing using TCAD Sentaurus simulation. A new approach was used to model the electrolyte, based on the literature, as the simulator previously lacked a model for this type of material. The simulation results show an increase in drain current levels for acidic pH values and a decrease for basic pH values. Additionally, the drain voltage demonstrates an influence on the electrolyte charges, which worsens the device sensitivity. Therefore, a new device was proposed, using only the source sensing region to avoid drain influence. This new device shows an improvement in sensitivity and optimizes the obtained results for future experimental analyses.

Universidade de São Paulo (BR)
Openalex Percentile: Top 85%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.