Critical evaluation of high-resolution and low-resolution mass spectrometry for biomonitoring of human environmental exposure to pesticides

Despite increasing debates about their potential side effects on human health, data concerning the risks and the impacts associated with pesticides remains scarce. Analytical tools allowing the measurement of most pesticides and/or their metabolites to which the population can be exposed are also of need. In the present study, the limits of detection (LODs) of 3 different screening procedures based on either Low-Resolution and High-Resolution Mass Spectrometry (LR-MS and HR-MS) for the determination of pesticides in serum (among which carbamates, dithiocarbamates, neonicotinoids, organochlorines, organophosphates and pyrethroids) were explored. For HR-MS, a quadrupole time-of-flight was used in positive and negative electrospray ionization modes and data were obtained from either a targeted scheduled MSMS acquisition (HR-MSMS) or a data-independent acquisition (HR-DIA). For LR-MS, a triple quadrupole was used and data were acquired with a classical multiple-reaction monitoring (MRM) mode. Depending on the approach, the LOD values varied from 0.05 to 10 ng/mL. For the lowest concentrations, the proportion of molecules detected was systematically greater for the LR-MS approach, while those of HR-MSMS were better than those of HR-DIA. These differences in the LOD values were confirmed in a sample of 174 serums in which LR-MRM detected 89 compounds while HR-MSMS and HR-DIA detected 79 and 75 compounds, respectively. Nevertheless, for environmental and occupational purposes, HRMS approach could probably be efficient to detect most of pesticides and their metabolites in human serum and could be suitable for human biomonitoring studies or fundamental research exploring the impact of exposure to pesticides on human health. • Exploring the impact pesticides on human health needs sensitive analytical tools. • Screening procedures are useful to evaluate occupational or environmental exposure. • HR-MS is suitable for human biomonitoring studies or fundamental research.

Authors

Institutions

Publication Details

Journal
Environmental Technology & Innovation
Published
2024-09-19
DOI
https://doi.org/10.1016/j.eti.2024.103834
Citations
3
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
1.05
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Critical evaluation of high-resolution and low-resolution mass spectrometry for biomonitoring of human environmental exposure to pesticides

Souleiman El Balkhi, Franck Saint‐Marcoux, Elies Zarrouk
3 citations
Environmental Technology & Innovation
Pesticide Residue Analysis and Safety
1.05
article

Critical evaluation of high-resolution and low-resolution mass spectrometry for biomonitoring of human environmental exposure to pesticides

Souleiman El Balkhi, Franck Saint‐Marcoux, Elies Zarrouk
article en
3 citations

Abstract

Despite increasing debates about their potential side effects on human health, data concerning the risks and the impacts associated with pesticides remains scarce. Analytical tools allowing the measurement of most pesticides and/or their metabolites to which the population can be exposed are also of need. In the present study, the limits of detection (LODs) of 3 different screening procedures based on either Low-Resolution and High-Resolution Mass Spectrometry (LR-MS and HR-MS) for the determination of pesticides in serum (among which carbamates, dithiocarbamates, neonicotinoids, organochlorines, organophosphates and pyrethroids) were explored. For HR-MS, a quadrupole time-of-flight was used in positive and negative electrospray ionization modes and data were obtained from either a targeted scheduled MSMS acquisition (HR-MSMS) or a data-independent acquisition (HR-DIA). For LR-MS, a triple quadrupole was used and data were acquired with a classical multiple-reaction monitoring (MRM) mode. Depending on the approach, the LOD values varied from 0.05 to 10 ng/mL. For the lowest concentrations, the proportion of molecules detected was systematically greater for the LR-MS approach, while those of HR-MSMS were better than those of HR-DIA. These differences in the LOD values were confirmed in a sample of 174 serums in which LR-MRM detected 89 compounds while HR-MSMS and HR-DIA detected 79 and 75 compounds, respectively. Nevertheless, for environmental and occupational purposes, HRMS approach could probably be efficient to detect most of pesticides and their metabolites in human serum and could be suitable for human biomonitoring studies or fundamental research exploring the impact of exposure to pesticides on human health. • Exploring the impact pesticides on human health needs sensitive analytical tools. • Screening procedures are useful to evaluate occupational or environmental exposure. • HR-MS is suitable for human biomonitoring studies or fundamental research.

Environmental Technology & InnovationVol. 36
Centre Hospitalier Universitaire de Limoges (FR), Université de Limoges (FR)
Zero hunger
Openalex Percentile: Top 23%
Pesticide Residue Analysis and Safety
1.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.