Uncertainty Analysis of Traceable Measurements of Pulsed Magnetic Fields Used in Magnetotherapy

Low-frequency pulsed magnetic fields (PMFs) are often used in magnetotherapy for noninvasive therapy of muscles or bones. An oscilloscope with some kind of search coil or pickup coil can be used for measuring a PMF value. The integration of the induced voltage from the search coil using an integrator is needed in order to calculate the measured value. This article presents a traceable method with a PCB search coil and with a digital oscilloscope for measuring the PMF directly from the induced voltage without using an integrator. A detailed uncertainty analysis has been described. The method has been tested on PMF signals with repeating frequencies of 40 and 140 Hz. A comparison was performed between the use of an 8 bit (DSO-X 4024A) and a 16 bit (PicoScope 5444D) digital oscilloscope. Furthermore, the method was improved using a 3458A digital multimeter as a digitizer, which significantly reduced the expanded uncertainty of the measurement. The measurement results obtained using the 3458A multimeter were compared to the results obtained using digital oscilloscopes and also with measurements obtained by some commercial teslameters with Hall probes.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Magnetics
Published
2024-09-19
DOI
https://doi.org/10.1109/tmag.2024.3463701
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty Analysis of Traceable Measurements of Pulsed Magnetic Fields Used in Magnetotherapy

Michal Ulvr
IEEE Transactions on Magnetics
Nuclear Physics and Applications
article

Uncertainty Analysis of Traceable Measurements of Pulsed Magnetic Fields Used in Magnetotherapy

Michal Ulvr
article en

Abstract

Low-frequency pulsed magnetic fields (PMFs) are often used in magnetotherapy for noninvasive therapy of muscles or bones. An oscilloscope with some kind of search coil or pickup coil can be used for measuring a PMF value. The integration of the induced voltage from the search coil using an integrator is needed in order to calculate the measured value. This article presents a traceable method with a PCB search coil and with a digital oscilloscope for measuring the PMF directly from the induced voltage without using an integrator. A detailed uncertainty analysis has been described. The method has been tested on PMF signals with repeating frequencies of 40 and 140 Hz. A comparison was performed between the use of an 8 bit (DSO-X 4024A) and a 16 bit (PicoScope 5444D) digital oscilloscope. Furthermore, the method was improved using a 3458A digital multimeter as a digitizer, which significantly reduced the expanded uncertainty of the measurement. The measurement results obtained using the 3458A multimeter were compared to the results obtained using digital oscilloscopes and also with measurements obtained by some commercial teslameters with Hall probes.

IEEE Transactions on MagneticsVol. 61(6)
Český metrologický institut (CZ)
Ministerstvo Průmyslu a Obchodu
Openalex Percentile: Top 79%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Uncertainty Analysis of Traceable Measurements of Pulsed Magnetic Fields Used in Magnetotherapy — Michal Ulvr · IEEE Transactions on Magnetics (2024) | TGRS Research Map | TGRS