Design and Development of a Green Mobile Air Conditioning System for Electric Vehicles

<div class="section abstract"><div class="htmlview paragraph">Electric Vehicles (EVs) have rapidly grown as a means for clean mobility, as they zero down tail pipe emission of greenhouse gases. Additionally, greenhouse gases such as Hydro-Fluoro-Carbon (HFCs) based refrigerants used in Mobile Air-Conditioning (MAC) are under global scrutiny for their high Global Warming Potential (GWP). To prevent earth environment to pass the climate tipping point that will be irreversible within human capacity, actions such as rapid phase down of high GWP rated HFCs under Kigali Amendment to Montreal Protocol are enacted. India being amongst signatory nations is now working to fast track phase-down use of high GWP refrigerant and transit to low GWP refrigerant options. Nearly half of national HFCs use and emissions are for manufacture and service MAC. Vehicle OEMs supplying to markets in developing countries (e.g. European nation and non-Article 5 Parties) have already phased out HFC-134a (GWP=1400) through alternate refrigerant solutions.</div><div class="htmlview paragraph">The work presented here discusses a novel methodology to use sustainable low GWP refrigerant-based MACs in EVs. The existing MAC system operates through dual DX (Direct expansion) system cooling loop, one for cabin cooling requirement and another to ensure optimum cell temperature of high voltage battery. The refrigerant HFC-134a is not sustainable. To meet global commitments, alternative low GWP options such as R152a (GWP=124) can be considered. The superior thermal properties and low direct cost of R152a, makes it a suitable alternative to HFC-134a. The work also discusses development of intelligently controlled Secondary Loop-Mobile Air Conditioning (SL-MAC) system to address operational constraint with mildly flammable nature of R152a. In the proposed architecture, R152a is use as primary medium to produce refrigeration effect to cool the coolant by deploying chiller unit. The cooled coolant is then circulated in secondary loop comprising of two parallel cooling loops, to extract heat from cabin and HV battery systems. Suitable decision matrices have been consider to design the SLMAC configuration and components involved with it. Cooling performance have been compared basis the transition from DX system with HFC-134a to SLMAC system with R152a refrigerant, together with gap analysis and proposed solutions for bridging performance gaps.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2024-09-19
DOI
https://doi.org/10.4271/2024-28-0108
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Development of a Green Mobile Air Conditioning System for Electric Vehicles

Farhan Khan, Sangeet Kapoor, Santosh Venu, Anurag Maurya
SAE technical papers on CD-ROM/SAE technical paper series
Refrigeration and Air Conditioning Technologies
article

Design and Development of a Green Mobile Air Conditioning System for Electric Vehicles

Farhan Khan, Sangeet Kapoor, Santosh Venu, Anurag Maurya
article en

Abstract

<div class="section abstract"><div class="htmlview paragraph">Electric Vehicles (EVs) have rapidly grown as a means for clean mobility, as they zero down tail pipe emission of greenhouse gases. Additionally, greenhouse gases such as Hydro-Fluoro-Carbon (HFCs) based refrigerants used in Mobile Air-Conditioning (MAC) are under global scrutiny for their high Global Warming Potential (GWP). To prevent earth environment to pass the climate tipping point that will be irreversible within human capacity, actions such as rapid phase down of high GWP rated HFCs under Kigali Amendment to Montreal Protocol are enacted. India being amongst signatory nations is now working to fast track phase-down use of high GWP refrigerant and transit to low GWP refrigerant options. Nearly half of national HFCs use and emissions are for manufacture and service MAC. Vehicle OEMs supplying to markets in developing countries (e.g. European nation and non-Article 5 Parties) have already phased out HFC-134a (GWP=1400) through alternate refrigerant solutions.</div><div class="htmlview paragraph">The work presented here discusses a novel methodology to use sustainable low GWP refrigerant-based MACs in EVs. The existing MAC system operates through dual DX (Direct expansion) system cooling loop, one for cabin cooling requirement and another to ensure optimum cell temperature of high voltage battery. The refrigerant HFC-134a is not sustainable. To meet global commitments, alternative low GWP options such as R152a (GWP=124) can be considered. The superior thermal properties and low direct cost of R152a, makes it a suitable alternative to HFC-134a. The work also discusses development of intelligently controlled Secondary Loop-Mobile Air Conditioning (SL-MAC) system to address operational constraint with mildly flammable nature of R152a. In the proposed architecture, R152a is use as primary medium to produce refrigeration effect to cool the coolant by deploying chiller unit. The cooled coolant is then circulated in secondary loop comprising of two parallel cooling loops, to extract heat from cabin and HV battery systems. Suitable decision matrices have been consider to design the SLMAC configuration and components involved with it. Cooling performance have been compared basis the transition from DX system with HFC-134a to SLMAC system with R152a refrigerant, together with gap analysis and proposed solutions for bridging performance gaps.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Tata Motors (India) (IN)
Industry, innovation and infrastructure
Openalex Percentile: Top 85%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.