A Self-Decoupling Three-Segment Continuum Flexible Robot Based on Stiffness Difference

The coupling effect of the flexible robotic arm with multiple degrees of freedom greatly increases the control complexity. For flexible endoscopic robots that manipulate an endoscope or other necessary channels like gas detection channel, its performance, like adaptability to tortuous paths, simplicity of control, and compactness of size are essential. Currently, there is a tradeoff between multiple-degree of freedom (DOF) and control accuracy of continuum robots. In this article, a self-decoupling continuum robot with multiple stiffness was proposed. Based on the difference in stiffness among segments, the proposed robotic arm can well realize the independent operation of each DOF. Using stiffness analysis and kinematics calculation, the optimal self-decoupling structure model of the robot was determined. With finite element analysis and experimental verification, the control error of the proposed robotic arm is less than 2.5%. The coupling error among segments is less than 6.7%, and the ratio of absolute maximum error to the length of the robotic arm is less than 1.4%.

Authors

Institutions

Publication Details

Journal
IEEE/ASME Transactions on Mechatronics
Published
2024-09-19
DOI
https://doi.org/10.1109/tmech.2024.3454204
Citations
3
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Self-Decoupling Three-Segment Continuum Flexible Robot Based on Stiffness Difference

Qiqi Pan, Yongfei Feng, Jingjing Luo, Li Chen et al.
3 citations
IEEE/ASME Transactions on Mechatronics
Soft Robotics and Applications
0.55
article

A Self-Decoupling Three-Segment Continuum Flexible Robot Based on Stiffness Difference

Qiqi Pan, Yongfei Feng, Jingjing Luo, Li Chen, Hongbo Wang
article en
3 citations

Abstract

The coupling effect of the flexible robotic arm with multiple degrees of freedom greatly increases the control complexity. For flexible endoscopic robots that manipulate an endoscope or other necessary channels like gas detection channel, its performance, like adaptability to tortuous paths, simplicity of control, and compactness of size are essential. Currently, there is a tradeoff between multiple-degree of freedom (DOF) and control accuracy of continuum robots. In this article, a self-decoupling continuum robot with multiple stiffness was proposed. Based on the difference in stiffness among segments, the proposed robotic arm can well realize the independent operation of each DOF. Using stiffness analysis and kinematics calculation, the optimal self-decoupling structure model of the robot was determined. With finite element analysis and experimental verification, the control error of the proposed robotic arm is less than 2.5%. The coupling error among segments is less than 6.7%, and the ratio of absolute maximum error to the length of the robotic arm is less than 1.4%.

IEEE/ASME Transactions on MechatronicsVol. 30(4)
Fudan University (CN)
Science and Technology Commission of Shanghai Municipality
Openalex Percentile: Top 37%
Soft Robotics and Applications
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.