Open-Circuit Fault-Tolerant Control for DTP-SynRM Based on Rotation Coordinate Transformation

This article proposes an open-circuit fault-tolerant strategy for a dual-three-phase synchronous reluctance motor (DTP-SynRM) based on rotation coordinate transformation. A DTP-SynRM vector space decoupling model is established to achieve complete decoupling of voltage, current, and flux equations. Then, the influence of the fault state on the current and the torque fluctuations of the motor is analyzed. The proposed fault-tolerant strategy converts the second harmonic of the current through rotational coordinate transformation, thereby directly controlling the second harmonic of the current using a proportional–integral regulator in the new coordinate system. The simulation results prove the analysis and the effectiveness of the proposed strategy.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Applied Superconductivity
Published
2024-09-19
DOI
https://doi.org/10.1109/tasc.2024.3465372
Primary Topic
Advanced Memory and Neural Computing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Open-Circuit Fault-Tolerant Control for DTP-SynRM Based on Rotation Coordinate Transformation

Lijun Xiao, Jibin Zou, Bingjun Li, Yongxiang Xu et al.
IEEE Transactions on Applied Superconductivity
Advanced Memory and Neural Computing
article

Open-Circuit Fault-Tolerant Control for DTP-SynRM Based on Rotation Coordinate Transformation

Lijun Xiao, Jibin Zou, Bingjun Li, Yongxiang Xu, Boyuan Zheng
article en

Abstract

This article proposes an open-circuit fault-tolerant strategy for a dual-three-phase synchronous reluctance motor (DTP-SynRM) based on rotation coordinate transformation. A DTP-SynRM vector space decoupling model is established to achieve complete decoupling of voltage, current, and flux equations. Then, the influence of the fault state on the current and the torque fluctuations of the motor is analyzed. The proposed fault-tolerant strategy converts the second harmonic of the current through rotational coordinate transformation, thereby directly controlling the second harmonic of the current using a proportional–integral regulator in the new coordinate system. The simulation results prove the analysis and the effectiveness of the proposed strategy.

IEEE Transactions on Applied SuperconductivityVol. 34(8)
Harbin Engineering University (CN), Harbin Institute of Technology (CN)
Climate action
Openalex Percentile: Top 87%
Advanced Memory and Neural Computing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.