Wireless Electromagnetic Sensors for Image-Guided Cardiothoracic Procedures
Electromagnetic tracking (EMT) is essential in surgical navigation without line of sight and to reduce the use of harmful radiation-based imaging. The inductive sensors used in current EMT systems are small, often less than a millimeter in diameter, but the need for a wired connection from the sensor to the control unit can cause obstructions and complicate the surgical field. This work introduces a novel wireless method of tracking electromagnetic (EM) sensors with immediate applications intended to streamline surgical workflows. Wireless EM 6-degree-of-freedom (DOF) sensor nodes were designed and manufactured with the intended use as a patient-mounted registration device. The battery-powered prototype device was shown to have a position and orientation trueness of 0.84 mm and 0.7°, respectively, over a tracking volume of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$40\times 40\times 35$ </tex-math></inline-formula> cm. The sensor node performs analog and digital signal processing and uses bluetooth low energy (BLE) to transmit the sensor data at a 25-Hz refresh rate. The Bluetooth-based wireless EM sensor nodes developed in this work have comparable performance to standard wired sensors and were tested in both a static volume characterization and a dynamic ex vivo lung model. The work in this article is based on the open-source Anser EMT system although the approach can be generalized to any tracking system. Wireless EMT offers the potential to introduce computer-assisted navigation in surgical procedures where wired sensors were previously infeasible.
Authors
- Pádraig Cantillon‐Murphy (ORCID: https://orcid.org/0000-0001-6679-2889)
- Marco Cavaliere (ORCID: https://orcid.org/0000-0003-1901-0041)
- Charu Pande (ORCID: https://orcid.org/0000-0002-4026-1489)
- Daragh Crowley (ORCID: https://orcid.org/0000-0002-4268-7504)
- Herman Alexander Jaeger (ORCID: https://orcid.org/0000-0003-4771-8469)
- E. F. Higgins (ORCID: https://orcid.org/0009-0008-7116-9301)
- Kilian O’Donoghue
Institutions
- National University of Ireland (IE)
- University College Cork (IE)
- Farran Technology (Ireland) (IE)
- International Energy Research Centre (IE)
Publication Details
- Journal
- IEEE Sensors Journal
- Published
- 2024-09-19
- DOI
- https://doi.org/10.1109/jsen.2024.3458454
- Citations
- 3
- Primary Topic
- Wireless Power Transfer Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.63
Funders
- Science Foundation Ireland
- H2020 European Research Council