Failure Analysis of a Welded 316L Stainless-Steel Stack with Premature Damage Due to Stress-Corrosion Cracking
Abstract This study analyzed the premature failure of a stainless-steel stack obtained from a mining company. The stack was manufactured using ASTM A240 Type 316L stainless steel. After one year of its service, massive leakages and cracks were observed near the welds. Following a visual examination of the stack, a representative sample was extracted and analyzed using visual and radiographic inspection, metallographic examination, scanning electron microscopy, energy-dispersive spectrometry, optical emission spectrometry, ferrite number analysis, and leak testing. Furthermore, corrosion mechanisms and the sequence of events leading to failure were determined. Two different mechanisms were identified: acid dew point corrosion caused by the condensation of H 2 SO 4 and HCl at the inner walls of the chimney, followed by stress-corrosion cracking near the welded joints.
Authors
- J. Giraldo (ORCID: https://orcid.org/0000-0001-6614-0661)
- Juan Felipe Santa (ORCID: https://orcid.org/0000-0001-5781-672X)
- Henry León‐Henao (ORCID: https://orcid.org/0000-0002-1582-9386)
- John E Morales-Galeano
Institutions
- Universidad Nacional de Colombia (CO)
- Universidad de Medellín (CO)
- The Ohio State University (US)
Publication Details
- Journal
- Journal of Failure Analysis and Prevention
- Published
- 2024-09-19
- DOI
- https://doi.org/10.1007/s11668-024-01990-y
- Citations
- 6
- Primary Topic
- Hydrogen embrittlement and corrosion behaviors in metals
- Type
- article
- Field-Weighted Citation Impact
- 1.03
Funders
- Universidad Nacional de Colombia