Fan assisted extraction and low pressure chromatographic system with a phenyl monolithic column for amperometric determination of volatile α-dicarbonyl compounds in coffee brews

• Low pressure liquid chromatography based on a 5 mm length phenyl monolithic column. • Fan assisted extraction system as a mean to perform full evaporation technique. • Amperometric determination of volatile α-dicarbonyl compounds in brewed coffees. • Acetonitrile consumption of ca. 0.45 mL per analysis. In this work, a low pressure chromatographic system featuring a single 0.5 cm length phenyl monolithic column and an amperometric detector was developed to determine volatile ⍺-dicarbonyl compounds in coffee brews. The analytical strategy relied on the extraction of the volatile ⍺-dicarbonyl compounds and their derivatization with o -phenylenediamine, prior to the determination of the resulting quinoxaline derivative compounds in the designed chromatographic system. The studies of the mobile phase composition and electrochemical conditions are presented. The extraction of the volatile ⍺-dicarbonyl compounds was performed resourcing to a recent approach based on the fan assisted extraction system. This system performs the full evaporation technique and allowed the quantitative recovery (>85 %) of diacetyl and 2,3-pentanedione from the coffee brew based on the following experimental conditions: sample volume 30 µL, extraction period 15 min, acceptor solution (water, acetonitrile, 90:10, v/v) volume 400 µL, and sample temperature 50 °C. The developed method showed no matrix effect for different coffee brews and the quantification of the studied analytes can be performed through the external calibration method. Detection limits of 3.6 × 10 −6 mol/L for diacetyl and 12.9 × 10 −6 mol/L for 2,3-pentanedione were obtained. Sample analysis rate was of 5 h −1 and the acetonitrile consumption was of ca. 450 µL per chromatographic run.

Authors

Institutions

Publication Details

Journal
Microchemical Journal
Published
2024-09-19
DOI
https://doi.org/10.1016/j.microc.2024.111689
Citations
3
Primary Topic
Coffee research and impacts
Type
article
Field-Weighted Citation Impact
1.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fan assisted extraction and low pressure chromatographic system with a phenyl monolithic column for amperometric determination of volatile α-dicarbonyl compounds in coffee brews

João Rodrigo Santos, Paulo Almeida, Alexandra Rangel Silva
3 citations
Microchemical Journal
Coffee research and impacts
1.34
article

Fan assisted extraction and low pressure chromatographic system with a phenyl monolithic column for amperometric determination of volatile α-dicarbonyl compounds in coffee brews

João Rodrigo Santos, Paulo Almeida, Alexandra Rangel Silva
article en
3 citations

Abstract

• Low pressure liquid chromatography based on a 5 mm length phenyl monolithic column. • Fan assisted extraction system as a mean to perform full evaporation technique. • Amperometric determination of volatile α-dicarbonyl compounds in brewed coffees. • Acetonitrile consumption of ca. 0.45 mL per analysis. In this work, a low pressure chromatographic system featuring a single 0.5 cm length phenyl monolithic column and an amperometric detector was developed to determine volatile ⍺-dicarbonyl compounds in coffee brews. The analytical strategy relied on the extraction of the volatile ⍺-dicarbonyl compounds and their derivatization with o -phenylenediamine, prior to the determination of the resulting quinoxaline derivative compounds in the designed chromatographic system. The studies of the mobile phase composition and electrochemical conditions are presented. The extraction of the volatile ⍺-dicarbonyl compounds was performed resourcing to a recent approach based on the fan assisted extraction system. This system performs the full evaporation technique and allowed the quantitative recovery (>85 %) of diacetyl and 2,3-pentanedione from the coffee brew based on the following experimental conditions: sample volume 30 µL, extraction period 15 min, acceptor solution (water, acetonitrile, 90:10, v/v) volume 400 µL, and sample temperature 50 °C. The developed method showed no matrix effect for different coffee brews and the quantification of the studied analytes can be performed through the external calibration method. Detection limits of 3.6 × 10 −6 mol/L for diacetyl and 12.9 × 10 −6 mol/L for 2,3-pentanedione were obtained. Sample analysis rate was of 5 h −1 and the acetonitrile consumption was of ca. 450 µL per chromatographic run.

Microchemical JournalVol. 207
Universidade do Porto (PT), Rede de Química e Tecnologia (PT)
Fundação para a Ciência e a Tecnologia
Openalex Percentile: Top 19%
Coffee research and impacts
1.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.