Failure Analysis of Ni-8YSZ Electrode under Reoxidation Based on the Real Microstructure

During the operation of solid oxide fuel cells (SOFCs), the Ni-8YSZ anodes are subjected to thermal mismatch and reoxidation, accompanied by the risk of damage and failure. These damages and failures are generally induced by small defects at the microscopic level, leading to the degradation of the structural bearing capacity. Therefore, the distribution and quantification of the stresses in the real microstructure of Ni-8YSZ electrodes is essential. In this study, the real Ni-8YSZ microstructure was reconstructed based on nano-computed tomography, and the stress distribution of the real microstructure was analyzed based on the finite element method under reoxidation and different operating temperatures. The failure probability of 8YSZ at different degrees of reoxidation was evaluated according to the Weibull method, and the amount of damaged 8YSZ elements was statistically counted. The study results indicate a high level of stress in the thin necks and relatively sharp areas of the microstructure. The 8YSZ has a high failure probability at a reoxidation extent of 5-10%.

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-09-19
DOI
https://doi.org/10.3390/ma17184599
Citations
4
Primary Topic
Advancements in Solid Oxide Fuel Cells
Type
article
Field-Weighted Citation Impact
0.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Failure Analysis of Ni-8YSZ Electrode under Reoxidation Based on the Real Microstructure

Jinzhi Li, Jiamiao Xie, Wenqian Hao, Zhipeng Chen et al.
4 citations
Materials
Advancements in Solid Oxide Fuel Cells
0.47
article

Failure Analysis of Ni-8YSZ Electrode under Reoxidation Based on the Real Microstructure

Jinzhi Li, Jiamiao Xie, Wenqian Hao, Zhipeng Chen, Fenghui Wang, Hongye Zhang, Sen Yang, Xiang Zhao
article en
4 citations

Abstract

During the operation of solid oxide fuel cells (SOFCs), the Ni-8YSZ anodes are subjected to thermal mismatch and reoxidation, accompanied by the risk of damage and failure. These damages and failures are generally induced by small defects at the microscopic level, leading to the degradation of the structural bearing capacity. Therefore, the distribution and quantification of the stresses in the real microstructure of Ni-8YSZ electrodes is essential. In this study, the real Ni-8YSZ microstructure was reconstructed based on nano-computed tomography, and the stress distribution of the real microstructure was analyzed based on the finite element method under reoxidation and different operating temperatures. The failure probability of 8YSZ at different degrees of reoxidation was evaluated according to the Weibull method, and the amount of damaged 8YSZ elements was statistically counted. The study results indicate a high level of stress in the thin necks and relatively sharp areas of the microstructure. The 8YSZ has a high failure probability at a reoxidation extent of 5-10%.

MaterialsVol. 17(18)
North University of China (CN), Northwestern Polytechnical University (CN), Songshan Lake Materials Laboratory (CN)
Chinese Academy of Sciences
Affordable and clean energy
Openalex Percentile: Top 38%
Advancements in Solid Oxide Fuel Cells
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Failure Analysis of Ni-8YSZ Electrode under Reoxidation Based on the Real Microstructure — Jinzhi Li, Jiamiao Xie, et al. · Materials (2024) | TGRS Research Map | TGRS