Holistic and in situ calibration method for a spectral-temporally modulated Mueller spectropolarimeter

The spectral-temporally modulated Mueller spectropolarimeter (STMSP) offers advantages of broader band limitation, better resolution, and faster detection speed. However, the current STMSP calibration method separates the polarization state generator and analyzer, necessitating subsequent recombination, which is inefficient and unstable. In this paper, a holistic and in situ calibration method for STMSP is proposed. It only requires insertion of a polarizer as a reference sample, eliminating the need for separate calibration and recombination. The STMSP is calibrated in situ as a whole, addressing the misalignment error of the spectral modulation module, the total polarimetric errors of the temporal modulation module, and the spectral modulation transfer function of the spectrometer. Experimental results demonstrate high accuracy, with a root mean square error (RMSE) of 0.0004, which is an order of magnitude lower than that of the dual-rotating retarder spectropolarimeter (DRRSP) after eigenvalue calibration. This demonstrates its potential for enabling faster and more accurate acquisition of the Mueller spectra.

Authors

Institutions

Publication Details

Journal
Applied Optics
Published
2024-09-19
DOI
https://doi.org/10.1364/ao.535139
Citations
2
Primary Topic
Optical Polarization and Ellipsometry
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Holistic and in situ calibration method for a spectral-temporally modulated Mueller spectropolarimeter

Hui Zhong, Xiang Ma, Jinxian Wu, Zhe Zhao et al.
2 citations
Applied Optics
Optical Polarization and Ellipsometry
0.37
article

Holistic and in situ calibration method for a spectral-temporally modulated Mueller spectropolarimeter

Hui Zhong, Xiang Ma, Jinxian Wu, Zhe Zhao, Yanqiu Li
article en
2 citations

Abstract

The spectral-temporally modulated Mueller spectropolarimeter (STMSP) offers advantages of broader band limitation, better resolution, and faster detection speed. However, the current STMSP calibration method separates the polarization state generator and analyzer, necessitating subsequent recombination, which is inefficient and unstable. In this paper, a holistic and in situ calibration method for STMSP is proposed. It only requires insertion of a polarizer as a reference sample, eliminating the need for separate calibration and recombination. The STMSP is calibrated in situ as a whole, addressing the misalignment error of the spectral modulation module, the total polarimetric errors of the temporal modulation module, and the spectral modulation transfer function of the spectrometer. Experimental results demonstrate high accuracy, with a root mean square error (RMSE) of 0.0004, which is an order of magnitude lower than that of the dual-rotating retarder spectropolarimeter (DRRSP) after eigenvalue calibration. This demonstrates its potential for enabling faster and more accurate acquisition of the Mueller spectra.

Applied OpticsVol. 63(29)
Beijing Institute of Technology (CN)
Climate action
Openalex Percentile: Top 44%
Optical Polarization and Ellipsometry
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Holistic and in situ calibration method for a spectral-temporally modulated Mueller spectropolarimeter — Hui Zhong, Xiang Ma, et al. · Applied Optics (2024) | TGRS Research Map | TGRS