[Accuracy of multi-task network based on vision Transformer in the three-dimensional upper airway analysis].

<b>Objective:</b> To explore the accuracy of a multi-task model based on vision Transformer for analyzing the three-dimensional (3D) upper airway and its subregions, and to evaluate its clinical applicability. <b>Methods:</b> According to the inclusion and exclusion criteria, cone-beam CT (CBCT) data of 10 patients [4 males and 6 females, (20.8±2.7) years] who had their first visit to the Department of Orthodontics in the Hospital of Stomatology, Wuhan University from January 2012 to January 2020 were retrospectively selected. The 3D slicer software was used to segment the upper airway and pharyngeal airway and measure their volumes as the gold standard. The Dolphin 3D software was used to segment the pharyngeal airway and its subregions and measure their volumes as the gold standard. A multi-task model based on vision Transformer developed by the research team for automatic segmentation and volume measurement of the upper airway and its subregions. All the measurements were conducted by the same attending physician. The Bland-Altman analysis and intraclass correlation coefficient (<i>ICC</i>) were used to evaluate the consistency between the multi-task network and the gold standard in the upper airway segmentation and volume measurements, and the paired <i>t</i> test was used to compare the differences between the multi-tasking model and the gold standard. <b>Results:</b> The mean volume deviation of the upper airway segmented by multi-task model and 3D Slicer was -979.6 mm<sup>3</sup>, and the <i>ICC</i> was 0.97. The mean volume deviation of the pharyngeal airway, nasopharynx, velopharynx, glossopharynx and hypopharynx segmented by multi-task network and Dolphin 3D were 2 069.5, -950.1, -823.6, -813.9 and 4 003.4 mm<sup>3</sup>, respectively. In addition, <i>ICC</i> in pharyngeal airway, nasopharynx, velopharynx, glossopharynx and hypopharynx were 0.97, 0.94, 0.96, 0.96 and 0.69, respectively. <b>Conclusions:</b> The multi-task model based on vision Transformer produced different errors in the segmentation of 3D upper airway and its subregions. The segmentation of the nasopharynx, velopharynx and glossopharynx was in good agreement with the gold standard, while the segmentation of hypopharynx was poor, suggesting that the robustness and generalization of this model should be further enhanced.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2024-09-09
DOI
https://doi.org/10.3760/cma.j.cn112144-20240514-00205
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Accuracy of multi-task network based on vision Transformer in the three-dimensional upper airway analysis].

Fang Chen, Xin‐Yuan Guan, Fang Hua, Hong He et al.
PubMed
Stroke Rehabilitation and Recovery
article

[Accuracy of multi-task network based on vision Transformer in the three-dimensional upper airway analysis].

Fang Chen, Xin‐Yuan Guan, Fang Hua, Hong He, Ho Jae Han, S H Jin
article en

Abstract

<b>Objective:</b> To explore the accuracy of a multi-task model based on vision Transformer for analyzing the three-dimensional (3D) upper airway and its subregions, and to evaluate its clinical applicability. <b>Methods:</b> According to the inclusion and exclusion criteria, cone-beam CT (CBCT) data of 10 patients [4 males and 6 females, (20.8±2.7) years] who had their first visit to the Department of Orthodontics in the Hospital of Stomatology, Wuhan University from January 2012 to January 2020 were retrospectively selected. The 3D slicer software was used to segment the upper airway and pharyngeal airway and measure their volumes as the gold standard. The Dolphin 3D software was used to segment the pharyngeal airway and its subregions and measure their volumes as the gold standard. A multi-task model based on vision Transformer developed by the research team for automatic segmentation and volume measurement of the upper airway and its subregions. All the measurements were conducted by the same attending physician. The Bland-Altman analysis and intraclass correlation coefficient (<i>ICC</i>) were used to evaluate the consistency between the multi-task network and the gold standard in the upper airway segmentation and volume measurements, and the paired <i>t</i> test was used to compare the differences between the multi-tasking model and the gold standard. <b>Results:</b> The mean volume deviation of the upper airway segmented by multi-task model and 3D Slicer was -979.6 mm<sup>3</sup>, and the <i>ICC</i> was 0.97. The mean volume deviation of the pharyngeal airway, nasopharynx, velopharynx, glossopharynx and hypopharynx segmented by multi-task network and Dolphin 3D were 2 069.5, -950.1, -823.6, -813.9 and 4 003.4 mm<sup>3</sup>, respectively. In addition, <i>ICC</i> in pharyngeal airway, nasopharynx, velopharynx, glossopharynx and hypopharynx were 0.97, 0.94, 0.96, 0.96 and 0.69, respectively. <b>Conclusions:</b> The multi-task model based on vision Transformer produced different errors in the segmentation of 3D upper airway and its subregions. The segmentation of the nasopharynx, velopharynx and glossopharynx was in good agreement with the gold standard, while the segmentation of hypopharynx was poor, suggesting that the robustness and generalization of this model should be further enhanced.

PubMedVol. 59(9)
Shanghai Jiao Tong University (CN), Wuhan University (CN), Tsinghua University (CN)
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.