Walking in a controlled ankle motion (CAM) boot: In-boot measurement of joint kinematics and kinetics

Research investigating ankle function during walking in a controlled ankle motion (CAM) boot has either placed markers on the outside of the boot or made major alterations to the structure of the CAM boot to uncover key landmarks. The aim of this study was to quantify joint kinematics and kinetics using "in-boot" skin markers whilst making only minimal structural alterations. Seventeen healthy participants walked at their preferred walking speed in two conditions: (1) in standard athletic trainers (ASICS patriot 8, ASICS Oceania Pty Ltd, USA), and (2) using a hard-cased CAM boot (Rebound® Air Walker, Össur, Iceland) fitted on the right foot. Kinematic measurements revealed that CAM boots restrict sagittal plane ankle range of motion to less than 5°, and to ∼3° in the frontal plane, which is a reduction of 85% and 73% compared to standard footwear, respectively (p < 0.001). This ankle restriction resulted in a reduction of ankle joint total limb work contribution from 38 ± 5% in normal footwear to 13 ± 4% in the CAM boot (p < 0.001). This study suggests that CAM boots do restrict the ankle joint's ability to effectively perform work during walking, which leads to compensatory mechanisms at the ipsilateral and contralateral hip and knee joints. Our findings align with previous research that employed "on-boot" kinematic measurements, so we conclude that in-boot approaches do not offer any benefit to the researcher and instead, on-boot measurements are suitable.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2024-09-16
DOI
https://doi.org/10.1016/j.jbiomech.2024.112327
Citations
3
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Walking in a controlled ankle motion (CAM) boot: In-boot measurement of joint kinematics and kinetics

Cleveland T. Barnett, David E. Lunn, Josh Walker, Richard A. Wilkins et al.
3 citations
Journal of Biomechanics
Lower Extremity Biomechanics and Pathologies
0.55
article

Walking in a controlled ankle motion (CAM) boot: In-boot measurement of joint kinematics and kinetics

Cleveland T. Barnett, David E. Lunn, Josh Walker, Richard A. Wilkins, Mason L Stolycia
article en
3 citations

Abstract

Research investigating ankle function during walking in a controlled ankle motion (CAM) boot has either placed markers on the outside of the boot or made major alterations to the structure of the CAM boot to uncover key landmarks. The aim of this study was to quantify joint kinematics and kinetics using "in-boot" skin markers whilst making only minimal structural alterations. Seventeen healthy participants walked at their preferred walking speed in two conditions: (1) in standard athletic trainers (ASICS patriot 8, ASICS Oceania Pty Ltd, USA), and (2) using a hard-cased CAM boot (Rebound® Air Walker, Össur, Iceland) fitted on the right foot. Kinematic measurements revealed that CAM boots restrict sagittal plane ankle range of motion to less than 5°, and to ∼3° in the frontal plane, which is a reduction of 85% and 73% compared to standard footwear, respectively (p < 0.001). This ankle restriction resulted in a reduction of ankle joint total limb work contribution from 38 ± 5% in normal footwear to 13 ± 4% in the CAM boot (p < 0.001). This study suggests that CAM boots do restrict the ankle joint's ability to effectively perform work during walking, which leads to compensatory mechanisms at the ipsilateral and contralateral hip and knee joints. Our findings align with previous research that employed "on-boot" kinematic measurements, so we conclude that in-boot approaches do not offer any benefit to the researcher and instead, on-boot measurements are suitable.

Journal of BiomechanicsVol. 176
Leeds Teaching Hospitals NHS Trust (GB), NIHR Leeds Musculoskeletal Biomedical Research Unit (GB), Nottingham Trent University (GB), Leeds Beckett University (GB)
Openalex Percentile: Top 37%
Lower Extremity Biomechanics and Pathologies
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.