Can the Newer Model of Breast-Specific Positron Emission Tomography Reduce the “Blind Area”?

<b>Objectives</b>: Breast-specific positron emission tomography (PET) provides higher sensitivity and spatial resolution than whole-body PET/CT, but it has a blind area. Mammary glands near the chest wall sometimes present outside the field of view (FOV). A newer, dedicated breast PET (dbPET) model has a cylindrical detector with a larger diameter than previous models, so it is expected to eliminate or reduce blind areas. This study aimed to compare breast images acquired on the new dbPET model with images acquired on an older dbPET model to evaluate blind area reduction. <b>Methods</b>: The nipple-to-chest wall distance (mm), maximum breast cross-sectional area at the FOV edge (cm<sup>2</sup>) on the dbPET transverse images of the scanners, and the effects of patient age and body mass index (BMI) were compared. <b>Results</b>: There was no significant difference in the nipple-to-chest wall distance between the models (<i>p</i> = 0.223). The maximum breast cross-sectional area at the FOV edge was significantly larger on the newer model's images (<i>p</i> < 0.001). There was no significant correlation between breast size and the rate of change in both parameters. <b>Conclusions</b>: The new ring-type dbPET scanners with larger diameter detectors did not reduce the blind area observed on older dbPET scanners.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-09-19
DOI
https://doi.org/10.3390/diagnostics14182068
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can the Newer Model of Breast-Specific Positron Emission Tomography Reduce the “Blind Area”?

Yoko Satoh, Jiro Ishida, Sayuri Ishida, Akinori Takenaka et al.
1 citations
Diagnostics
Medical Imaging Techniques and Applications
0.40
article

Can the Newer Model of Breast-Specific Positron Emission Tomography Reduce the “Blind Area”?

Yoko Satoh, Jiro Ishida, Sayuri Ishida, Akinori Takenaka, Hiroshi Toyama, Yoshitaka Inui, Shuji Bando
article en
1 citations

Abstract

<b>Objectives</b>: Breast-specific positron emission tomography (PET) provides higher sensitivity and spatial resolution than whole-body PET/CT, but it has a blind area. Mammary glands near the chest wall sometimes present outside the field of view (FOV). A newer, dedicated breast PET (dbPET) model has a cylindrical detector with a larger diameter than previous models, so it is expected to eliminate or reduce blind areas. This study aimed to compare breast images acquired on the new dbPET model with images acquired on an older dbPET model to evaluate blind area reduction. <b>Methods</b>: The nipple-to-chest wall distance (mm), maximum breast cross-sectional area at the FOV edge (cm<sup>2</sup>) on the dbPET transverse images of the scanners, and the effects of patient age and body mass index (BMI) were compared. <b>Results</b>: There was no significant difference in the nipple-to-chest wall distance between the models (<i>p</i> = 0.223). The maximum breast cross-sectional area at the FOV edge was significantly larger on the newer model's images (<i>p</i> < 0.001). There was no significant correlation between breast size and the rate of change in both parameters. <b>Conclusions</b>: The new ring-type dbPET scanners with larger diameter detectors did not reduce the blind area observed on older dbPET scanners.

DiagnosticsVol. 14(18)
Fujita Health University (JP)
Openalex Percentile: Top 35%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.