Mid-Term Clinical and Radiographic Results of Complex Hip Revision Arthroplasty Based on 3D Life-Sized Model: A Prospective Case Series

<b>Background:</b> The pre-operative three-dimensional (3D) assessment of acetabular bone defects may not be evaluated properly with conventional radiographic and computed tomography images. This paper reports mid-term clinical and radiographic outcomes of complex revision total hip arthroplasty (r-THA) based on a 3D life-sized printed model. <b>Methods:</b> Patients who underwent r-THA for septic or aseptic acetabular loosening with acetabular defects Paprosky types IIc, IIIa, and IIIb between 2019 and 2021 were included. The outcomes of the study were to determine clinical and radiographic assessment outcomes at the time of the last follow-up. <b>Results:</b> 25 patients with mean age of 62.9 ± 10.8 (18-83) years old were included. The mean Harris hip score improved from 34.8 ± 8.1 pre-operative to 81.6 ± 10.4 points (<i>p</i> < 0.001). The mean visual analog scale decreased from 6.7 ± 1.4 points pre-operative to 2.4 ± 1.0 points (<i>p</i> < 0.001). The mean limb length discrepancy improved from -2.0 ± 1.2 cm pre-operative to -0.6 ± 0.6 cm (<i>p</i> < 0.001). The mean vertical position of the center of rotation (COR) changed from 3.5 ± 1.7 cm pre-operative to 2.0 ± 0.7 cm (<i>p</i> < 0.05). The mean horizontal COR changed from 3.9 ± 1.5 cm pre-operative to 3.2 ± 0.5 cm (<i>p</i> < 0.05). The mean acetabular component abduction angle changed from 59.7° ± 29.6° pre-operative to 46° ± 3.9 (<i>p</i> < 0.05). <b>Conclusions:</b> A three-dimensional-printed model provides an effective connection between the pre-operative bone defects' evaluation and the intraoperative findings, enabling surgeons to select optimal surgical strategies.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-09-17
DOI
https://doi.org/10.3390/jcm13185496
Citations
2
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mid-Term Clinical and Radiographic Results of Complex Hip Revision Arthroplasty Based on 3D Life-Sized Model: A Prospective Case Series

Guido Grappiolo, Edoardo Guazzoni, Carlo Maria Favazzi, Alessandro Pisano et al.
2 citations
Journal of Clinical Medicine
Orthopaedic implants and arthroplasty
1.15
article

Mid-Term Clinical and Radiographic Results of Complex Hip Revision Arthroplasty Based on 3D Life-Sized Model: A Prospective Case Series

Guido Grappiolo, Edoardo Guazzoni, Carlo Maria Favazzi, Alessandro Pisano, Vincenzo Di Matteo, Emanuela Morenghi, Mattia Loppini, Francesco La Camera, Katia Chiappetta
article en
2 citations

Abstract

<b>Background:</b> The pre-operative three-dimensional (3D) assessment of acetabular bone defects may not be evaluated properly with conventional radiographic and computed tomography images. This paper reports mid-term clinical and radiographic outcomes of complex revision total hip arthroplasty (r-THA) based on a 3D life-sized printed model. <b>Methods:</b> Patients who underwent r-THA for septic or aseptic acetabular loosening with acetabular defects Paprosky types IIc, IIIa, and IIIb between 2019 and 2021 were included. The outcomes of the study were to determine clinical and radiographic assessment outcomes at the time of the last follow-up. <b>Results:</b> 25 patients with mean age of 62.9 ± 10.8 (18-83) years old were included. The mean Harris hip score improved from 34.8 ± 8.1 pre-operative to 81.6 ± 10.4 points (<i>p</i> < 0.001). The mean visual analog scale decreased from 6.7 ± 1.4 points pre-operative to 2.4 ± 1.0 points (<i>p</i> < 0.001). The mean limb length discrepancy improved from -2.0 ± 1.2 cm pre-operative to -0.6 ± 0.6 cm (<i>p</i> < 0.001). The mean vertical position of the center of rotation (COR) changed from 3.5 ± 1.7 cm pre-operative to 2.0 ± 0.7 cm (<i>p</i> < 0.05). The mean horizontal COR changed from 3.9 ± 1.5 cm pre-operative to 3.2 ± 0.5 cm (<i>p</i> < 0.05). The mean acetabular component abduction angle changed from 59.7° ± 29.6° pre-operative to 46° ± 3.9 (<i>p</i> < 0.05). <b>Conclusions:</b> A three-dimensional-printed model provides an effective connection between the pre-operative bone defects' evaluation and the intraoperative findings, enabling surgeons to select optimal surgical strategies.

Journal of Clinical MedicineVol. 13(18)
Humanitas University (IT), Agostino Gemelli University Polyclinic (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT), IRCCS Humanitas Research Hospital (IT), University of Genoa (IT)
Fondation pour la Recherche Médicale
Openalex Percentile: Top 21%
Orthopaedic implants and arthroplasty
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.