Manufacturing Process Affects Coagulation Kinetics of Ortho-R, an Injectable Chitosan–Platelet-Rich Plasma Biomaterial for Tissue Repair

Ortho-R (ChitogenX Inc., Kirkland, QC, Canada) is an injectable combination drug-biologic product that is used as an adjunct to augment the standard of care for the surgical repair of soft tissues. The drug product comprises lyophilized chitosan, trehalose and calcium chloride, and it is dissolved in platelet-rich plasma (PRP), a blood-derived biologic, prior to injection at the surgical site where it will coagulate. The first step of the Ortho-R manufacturing process involves dissolving the chitosan in hydrochloric acid. The purpose of this study was to investigate the effect of increasing the amount of acid used to dissolve the chitosan on final drug product performance, more specifically, on the chitosan-PRP coagulation kinetics. Chitosans were solubilized in hydrochloric acid, with concentrations adjusted to obtain between 60% and 95% protonation of the chitosan amino groups. Freeze-dried Ortho-R was solubilized with PRP, and coagulation was assessed using thromboelastography (TEG). The clotted mixtures were observed with histology. Clot reaction time (TEG R) increased and clot maximal amplitude (TEG MA) decreased with protonation levels as pH decreased. Chitosan distribution was homogeneous in chitosan-PRP clots at the lowest protonation levels, but it accumulated toward the surface of the clots at the highest protonation levels as pH decreased. These changes in coagulation kinetics, clot strength and chitosan distribution induced by high protonation of the chitosan amino groups were partially reversed by adding sodium hydroxide to the dissolved chitosan component in order to decrease pH. Careful control of manufacturing processes is critical, and it is important to consider the impact of each manufacturing step on product performance.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2024-09-17
DOI
https://doi.org/10.3390/bioengineering11090929
Citations
1
Primary Topic
Periodontal Regeneration and Treatments
Type
article
Field-Weighted Citation Impact
0.54

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Manufacturing Process Affects Coagulation Kinetics of Ortho-R, an Injectable Chitosan–Platelet-Rich Plasma Biomaterial for Tissue Repair

Marc Lavertu, Anik Chevrier
1 citations
Bioengineering
Periodontal Regeneration and Treatments
0.54
article

Manufacturing Process Affects Coagulation Kinetics of Ortho-R, an Injectable Chitosan–Platelet-Rich Plasma Biomaterial for Tissue Repair

Marc Lavertu, Anik Chevrier
article en
1 citations

Abstract

Ortho-R (ChitogenX Inc., Kirkland, QC, Canada) is an injectable combination drug-biologic product that is used as an adjunct to augment the standard of care for the surgical repair of soft tissues. The drug product comprises lyophilized chitosan, trehalose and calcium chloride, and it is dissolved in platelet-rich plasma (PRP), a blood-derived biologic, prior to injection at the surgical site where it will coagulate. The first step of the Ortho-R manufacturing process involves dissolving the chitosan in hydrochloric acid. The purpose of this study was to investigate the effect of increasing the amount of acid used to dissolve the chitosan on final drug product performance, more specifically, on the chitosan-PRP coagulation kinetics. Chitosans were solubilized in hydrochloric acid, with concentrations adjusted to obtain between 60% and 95% protonation of the chitosan amino groups. Freeze-dried Ortho-R was solubilized with PRP, and coagulation was assessed using thromboelastography (TEG). The clotted mixtures were observed with histology. Clot reaction time (TEG R) increased and clot maximal amplitude (TEG MA) decreased with protonation levels as pH decreased. Chitosan distribution was homogeneous in chitosan-PRP clots at the lowest protonation levels, but it accumulated toward the surface of the clots at the highest protonation levels as pH decreased. These changes in coagulation kinetics, clot strength and chitosan distribution induced by high protonation of the chitosan amino groups were partially reversed by adding sodium hydroxide to the dissolved chitosan component in order to decrease pH. Careful control of manufacturing processes is critical, and it is important to consider the impact of each manufacturing step on product performance.

BioengineeringVol. 11(9)
Polytechnique Montréal (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 31%
Periodontal Regeneration and Treatments
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Manufacturing Process Affects Coagulation Kinetics of Ortho-R, an Injectable Chitosan–Platelet-Rich Plasma Biomaterial for Tissue Repair — Marc Lavertu, Anik Chevrier · Bioengineering (2024) | TGRS Research Map | TGRS