MITIGATION OF POWER QUALITY PROBLEMS IN STEEL PLANTS USING STATIC SYNCHRONOUS COMPENSATOR

This paper focuses on mitigating various power quality issues from electric arc furnaces (EAF) in steel plants, including voltage flicker, sag, swell, and harmonics. Arc furnaces are recognized as one of the industry's most nonlinear electrically polluting loads. The proposed solution in this article to address all power quality issues caused by EAF is implementing a flexible power supply strategy known as a static synchronous compensator (STATCOM) for injecting reactive energy into the electrical grid. In this study, an experimental model of EAF is utilized based on real measurements of the variation of arc resistance and arc reactance during the melting phase. The pulse width modulation (PWM) technique is employed for current tracking feedback control to generate the required reactive current. A fuzzy logic controller (FLC) is employed for the DC bus.

Authors

Institutions

Publication Details

Journal
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Published
2024-09-15
DOI
https://doi.org/10.59277/rrst-ee.2024.69.3.6
Citations
1
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MITIGATION OF POWER QUALITY PROBLEMS IN STEEL PLANTS USING STATIC SYNCHRONOUS COMPENSATOR

Yacine Djeghader, Choayb Bousnoubra, Selma Allele
1 citations
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Power Quality and Harmonics
0.21
article

MITIGATION OF POWER QUALITY PROBLEMS IN STEEL PLANTS USING STATIC SYNCHRONOUS COMPENSATOR

Yacine Djeghader, Choayb Bousnoubra, Selma Allele
article en
1 citations

Abstract

This paper focuses on mitigating various power quality issues from electric arc furnaces (EAF) in steel plants, including voltage flicker, sag, swell, and harmonics. Arc furnaces are recognized as one of the industry's most nonlinear electrically polluting loads. The proposed solution in this article to address all power quality issues caused by EAF is implementing a flexible power supply strategy known as a static synchronous compensator (STATCOM) for injecting reactive energy into the electrical grid. In this study, an experimental model of EAF is utilized based on real measurements of the variation of arc resistance and arc reactance during the melting phase. The pulse width modulation (PWM) technique is employed for current tracking feedback control to generate the required reactive current. A fuzzy logic controller (FLC) is employed for the DC bus.

REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUEVol. 69(3)
Mohamed-Cherif Messaadia University (DZ)
Openalex Percentile: Top 48%
Power Quality and Harmonics
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

MITIGATION OF POWER QUALITY PROBLEMS IN STEEL PLANTS USING STATIC SYNCHRONOUS COMPENSATOR — Yacine Djeghader, Choayb Bousnoubra, et al. · REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE (2024) | TGRS Research Map | TGRS