Research on the attenuation of internal pressure in the large-span cylindrical roof building with a dominant gable opening

The internal to external pressure ratio in a large-span cylindrical roof building with a dominant gable opening fluctuates dramatically between 0 and 1, significantly impacted by the attenuation of internal pressure. Current theories usually assume this ratio equal to 1 and overlook the attenuation effect. This study investigates four cylindrical roof models with varying opening areas, scale ratios, and wind speeds by wind tunnel tests. It analyzes ratios of mean (C¯pi/C¯pe), fluctuating (σpi/σpe), and peak (Ĉpi/Ĉpe) internal to external pressure to pinpoint factors affecting the internal pressure attenuation. The results highlight that the most pronounced internal pressure attenuation is at the sideward opening. The vortex shedding around the opening is induced by the wind direction, scale ratio, and wind speed. The attenuation effect decreases with lower frequencies of periodic vortex shedding. This effect generally vanishes when the windward or leeward opening ratio (A1.5/V0) exceeds 0.57%. Empirical design formulas are proposed to predict ratios of internal to external pressure considering the attenuation effect. The inertia (CI) and loss coefficients (CL) affected by the internal pressure attenuation are analyzed to estimate the air slug inertia and damping through the opening. A governing equation, incorporating reduction coefficients (C¯eddy, C̃eddy) from empirical design formulas, is applied to precisely compute the attenuated internal pressure in the large-span cylindrical roof building with a dominant gable opening for engineering risk assessment.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2024-09-01
DOI
https://doi.org/10.1063/5.0220765
Citations
1
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the attenuation of internal pressure in the large-span cylindrical roof building with a dominant gable opening

Ying Sun, Qiming Zhu, Zhenggang Cao, Yuhang Ge
1 citations
Physics of Fluids
Vibration and Dynamic Analysis
0.33
article

Research on the attenuation of internal pressure in the large-span cylindrical roof building with a dominant gable opening

Ying Sun, Qiming Zhu, Zhenggang Cao, Yuhang Ge
article en
1 citations

Abstract

The internal to external pressure ratio in a large-span cylindrical roof building with a dominant gable opening fluctuates dramatically between 0 and 1, significantly impacted by the attenuation of internal pressure. Current theories usually assume this ratio equal to 1 and overlook the attenuation effect. This study investigates four cylindrical roof models with varying opening areas, scale ratios, and wind speeds by wind tunnel tests. It analyzes ratios of mean (C¯pi/C¯pe), fluctuating (σpi/σpe), and peak (Ĉpi/Ĉpe) internal to external pressure to pinpoint factors affecting the internal pressure attenuation. The results highlight that the most pronounced internal pressure attenuation is at the sideward opening. The vortex shedding around the opening is induced by the wind direction, scale ratio, and wind speed. The attenuation effect decreases with lower frequencies of periodic vortex shedding. This effect generally vanishes when the windward or leeward opening ratio (A1.5/V0) exceeds 0.57%. Empirical design formulas are proposed to predict ratios of internal to external pressure considering the attenuation effect. The inertia (CI) and loss coefficients (CL) affected by the internal pressure attenuation are analyzed to estimate the air slug inertia and damping through the opening. A governing equation, incorporating reduction coefficients (C¯eddy, C̃eddy) from empirical design formulas, is applied to precisely compute the attenuated internal pressure in the large-span cylindrical roof building with a dominant gable opening for engineering risk assessment.

Physics of FluidsVol. 36(9)
Harbin Institute of Technology (CN), Heilongjiang Institute of Technology (CN), Ministry of Industry and Information Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 42%
Vibration and Dynamic Analysis
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.