Analysis of the optical performance of intraocular lenses using profilometric measurements

What is known MTF(Modulation Transfer Function) through-focus curves (calculated in image space by moving the detector plane) can be obtained from optical bench assembly or from commercial devices. Recently, some studies proposed to characterize the lens surface design based on the profilometric measurements What is new A novel methodology based on profilometer measurements to assess the optical behaviour of Intraocular Lenses (IOls) was shown. The "Modulation Transfer Function through-object" based on vergence object displacement was introduced in order to analyse five premium IOLs. MTF through-object curve is more appropriate for studying clinical behaviour, as it provides further near and intermediate points distances and lower depth of focus around far peak compare to MTF through-focus curves. The optical behaviour of the five IOLs can vary considerably depending on the eye model and pupil size. The effect of tilt and decentration on the MTF through-object the IOLs was analysed.

Authors

Institutions

Publication Details

Journal
Graefe s Archive for Clinical and Experimental Ophthalmology
Published
2024-09-17
DOI
https://doi.org/10.1007/s00417-024-06628-1
Citations
5
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
1.93

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the optical performance of intraocular lenses using profilometric measurements

Teresa Caballero, Celia García, J.M. González-Leal, Vicente J. Camps et al.
5 citations
Graefe s Archive for Clinical and Experimental Ophthalmology
Ophthalmology and Visual Impairment Studies
1.93
article

Analysis of the optical performance of intraocular lenses using profilometric measurements

Teresa Caballero, Celia García, J.M. González-Leal, Vicente J. Camps, Juan J. Miret
article en
5 citations

Abstract

What is known MTF(Modulation Transfer Function) through-focus curves (calculated in image space by moving the detector plane) can be obtained from optical bench assembly or from commercial devices. Recently, some studies proposed to characterize the lens surface design based on the profilometric measurements What is new A novel methodology based on profilometer measurements to assess the optical behaviour of Intraocular Lenses (IOls) was shown. The "Modulation Transfer Function through-object" based on vergence object displacement was introduced in order to analyse five premium IOLs. MTF through-object curve is more appropriate for studying clinical behaviour, as it provides further near and intermediate points distances and lower depth of focus around far peak compare to MTF through-focus curves. The optical behaviour of the five IOLs can vary considerably depending on the eye model and pupil size. The effect of tilt and decentration on the MTF through-object the IOLs was analysed.

Graefe s Archive for Clinical and Experimental OphthalmologyVol. 263(2)
University of Alicante (ES), Universidad de Cádiz (ES)
Universidad de Alicante, Conselleria de Cultura, Educación y Ciencia, Generalitat Valenciana
Openalex Percentile: Top 13%
Ophthalmology and Visual Impairment Studies
1.93
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of the optical performance of intraocular lenses using profilometric measurements — Teresa Caballero, Celia García, et al. · Graefe s Archive for Clinical and Experimental Ophthalmology (2024) | TGRS Research Map | TGRS