Reslice3Dto2D: Introduction of a software tool to reformat 3D volumes into reference 2D slices in cardiovascular magnetic resonance imaging

The Reslice3Dto2D reformats 3D data at the exact location of a reference slice with a two-step-based interpolation in order to reflect in-plane discretization and through-plane slice thickness including a slice profile selection. The tool was successfully validated on an artificial dataset and tested on 119 subjects with different underlying pathologies. The exported reformatted data could be imported into three different post-processing software tools. The quantified image sharpness by the Frequency Domain Image Blur Measure was significantly decreased by around 40% on rectangular slice profiles with 7 mm slice thickness compared to 0 mm due to partial volume effects. Consequently, Reslice3Dto2D enables the quantification of 3D data with conventional post-processing tools as well as the comparison of 3D acquisitions with their established 2D version.

Authors

Institutions

Publication Details

Journal
BMC Research Notes
Published
2024-09-17
DOI
https://doi.org/10.1186/s13104-024-06931-4
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reslice3Dto2D: Introduction of a software tool to reformat 3D volumes into reference 2D slices in cardiovascular magnetic resonance imaging

Maximilian Fenski, Thomas H. Grandy, Darian Viezzer, Steffen Lange et al.
BMC Research Notes
Advanced MRI Techniques and Applications
article

Reslice3Dto2D: Introduction of a software tool to reformat 3D volumes into reference 2D slices in cardiovascular magnetic resonance imaging

Maximilian Fenski, Thomas H. Grandy, Darian Viezzer, Steffen Lange, Jeanette Schulz‐Menger, Thomas Hadler, Johanna Kuhnt
article en

Abstract

The Reslice3Dto2D reformats 3D data at the exact location of a reference slice with a two-step-based interpolation in order to reflect in-plane discretization and through-plane slice thickness including a slice profile selection. The tool was successfully validated on an artificial dataset and tested on 119 subjects with different underlying pathologies. The exported reformatted data could be imported into three different post-processing software tools. The quantified image sharpness by the Frequency Domain Image Blur Measure was significantly decreased by around 40% on rectangular slice profiles with 7 mm slice thickness compared to 0 mm due to partial volume effects. Consequently, Reslice3Dto2D enables the quantification of 3D data with conventional post-processing tools as well as the comparison of 3D acquisitions with their established 2D version.

BMC Research NotesVol. 17(1)
Darmstadt University of Applied Sciences (DE), Max Delbrück Center (DE), Humboldt-Universität zu Berlin (DE), German Centre for Cardiovascular Research (DE), Helios Hospital Berlin-Buch (DE), Charité - Universitätsmedizin Berlin (DE)
King's College London, Charité – Universitätsmedizin Berlin, Siemens Healthineers
Peace, Justice and strong institutions
Openalex Percentile: Top 74%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.