Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability

Low-keV VMI reconstructions at a level of 40-55 keV significantly improve image quality, vascular contrast, and the diagnostic assessability of the carotid artery compared with standard CT series in photon-counting CTA.

Authors

Institutions

Publication Details

Journal
La radiologia medica
Published
2024-09-17
DOI
https://doi.org/10.1007/s11547-024-01889-6
Citations
8
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
1.48
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability

Stephan Waldeck, Christian Booz, Mirela Dimitrova, Tommaso D’Angelo et al.
8 citations
La radiologia medica
Advanced X-ray and CT Imaging
1.48
article

Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability

Stephan Waldeck, Christian Booz, Mirela Dimitrova, Tommaso D’Angelo, Vitali Koch, Thomas Joseph Vogl, Silvio Mazziotti, Leon David Gruenewald, İbrahim Yel, Ludovica R. M. Lanzafame, Hanns Leonhard Kaatsch, Leona S. Alizadeh, Giuseppe Mauro Bucolo, Simon S. Martin, Aynur Goekduman, Daniel Overhoff
article en
8 citations

Abstract

Low-keV VMI reconstructions at a level of 40-55 keV significantly improve image quality, vascular contrast, and the diagnostic assessability of the carotid artery compared with standard CT series in photon-counting CTA.

La radiologia medicaVol. 129(11)
Goethe University Frankfurt (DE), Johannes Gutenberg University Mainz (DE), Heidelberg University (DE), Erasmus MC (NL), University Hospital Heidelberg (DE), University Medical Center of the Johannes Gutenberg University Mainz (DE), University Hospital Frankfurt (DE), Azienda Ospedaliera Universitaria Policlinico "G. Martino" (IT), University Medical Centre Mannheim (DE), Bundeswehrzentralkrankenhaus Koblenz (DE), Erasmus University Rotterdam (NL)
Affordable and clean energy
Openalex Percentile: Top 19%
Advanced X-ray and CT Imaging
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.