Phenylalanine: Amino Acid Metal Non-Enzymatic Electrochemical Voltammetric Sensors

This study presents a comparative analysis of non-enzymatic electrochemical voltammetric sensors, utilizing phenylalanine amino acid metal complexes (M: Ni, Zn, and Co) Polyaniline (PANI) nanocomposites (NCs). The PANI: Zn(Phala) 2 NCs-based sensor detected dopamine (DA) with a sensitivity of 101.18 μAμM −1 cm −2 . The limit of detection (LOD) for the PANI: Zn(Phala) 2 NCs-based sensor was calculated as 0.391 μM. This exceptional sensitivity makes the PANI: Zn(Phala) 2 NCs-based sensor highly promising for potential integration into biomedical test kits. To gain deeper insights into the structural properties of the PANI NCs, scanning electron microscopy (SEM), artificial-intelligence-based SEM, and Fourier transform infrared spectroscopy (FTIR) were employed for characterization. FTIR characterization provided insights into the functional groups of the NCs. The results of this comparative investigation a significant advancement in the field of PANI-based electrochemical sensors designed for DA sensing. The PANI: Zn(Phala) 2 NCs-based sensor show great promise for a range of advanced sensing applications. The Z value of the PANI: Zn(Phala) 2 NCs-based sensor is the lowest among the tested materials, indicating that the conductivity of the PANI: Zn(Phala) 2 layer is higher than that of other active layers. Consequently, the PANI: Zn(Phala) 2 NCs-based sensor achieved higher sensitivity in DA detection.

Authors

Publication Details

Journal
Journal of The Electrochemical Society
Published
2024-09-02
DOI
https://doi.org/10.1149/1945-7111/ad7c80
Citations
3
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phenylalanine: Amino Acid Metal Non-Enzymatic Electrochemical Voltammetric Sensors

Nevin Taşaltın, Dursun Ali Köse, Dilber Esra Yıldız, Selcan Karakuş et al.
3 citations
Journal of The Electrochemical Society
Advanced Chemical Sensor Technologies
0.55
article

Phenylalanine: Amino Acid Metal Non-Enzymatic Electrochemical Voltammetric Sensors

Nevin Taşaltın, Dursun Ali Köse, Dilber Esra Yıldız, Selcan Karakuş, Gökçe Göksu Gürsu, Gülsen Baytemir
article en
3 citations

Abstract

This study presents a comparative analysis of non-enzymatic electrochemical voltammetric sensors, utilizing phenylalanine amino acid metal complexes (M: Ni, Zn, and Co) Polyaniline (PANI) nanocomposites (NCs). The PANI: Zn(Phala) 2 NCs-based sensor detected dopamine (DA) with a sensitivity of 101.18 μAμM −1 cm −2 . The limit of detection (LOD) for the PANI: Zn(Phala) 2 NCs-based sensor was calculated as 0.391 μM. This exceptional sensitivity makes the PANI: Zn(Phala) 2 NCs-based sensor highly promising for potential integration into biomedical test kits. To gain deeper insights into the structural properties of the PANI NCs, scanning electron microscopy (SEM), artificial-intelligence-based SEM, and Fourier transform infrared spectroscopy (FTIR) were employed for characterization. FTIR characterization provided insights into the functional groups of the NCs. The results of this comparative investigation a significant advancement in the field of PANI-based electrochemical sensors designed for DA sensing. The PANI: Zn(Phala) 2 NCs-based sensor show great promise for a range of advanced sensing applications. The Z value of the PANI: Zn(Phala) 2 NCs-based sensor is the lowest among the tested materials, indicating that the conductivity of the PANI: Zn(Phala) 2 layer is higher than that of other active layers. Consequently, the PANI: Zn(Phala) 2 NCs-based sensor achieved higher sensitivity in DA detection.

Journal of The Electrochemical SocietyVol. 171(9)
Openalex Percentile: Top 37%
Advanced Chemical Sensor Technologies
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.