Exploring 3D Printed Implants With Anti-Dropout Function to Overcome Time Constraints in Acute Orbital Fractures for Patient-Specific Implants

Orbital wall reconstruction and implant insertion are crucial procedures for temporarily replacing the orbital walls in cases of significant fractures. Traditional methods using planar orbital implants have faced challenges owing to their flat shape, which increases the risk of dislocation from improper cuts and necessitates the use of screws in the orbital rim. This study aims to improve outcomes by employing customized 3-dimensional implants, thereby reducing complications and risk of dislocation resulting from external shock or implant weight postinsertion. This prospective study included 12 Korean individuals diagnosed with facial fractures (orbital wall injuries). Surgeries were performed on 12 patients, and follow-up CT scans were conducted on 10 of them. Therefore, the authors could only address the results for the 10 patients. The authors used bioactive glass ceramics and medical-grade poly-e-caprolactone to 3D print personalized implants, completing the manufacturing process in an average of 4.6 days. Computed tomography scans guided measurements of orbital volumes and exophthalmos. After surgery, we found that the difference values for bone orbital volumes (<0.1 mL) and exophthalmos (<1 mm except one) decreased compared with presurgery values. Independent t tests and Pearson correlation analysis revealed no significant changes between normal and affected sides in both phases. However, R-values increased in the postsurgery phase. Patients monitored postsurgery at 2 weeks, 3 months, and 6 months showed no complications. The 3D-printed patient-specific implants, customized to individual fracture shapes and featuring distinct implants and locking parts with notches, effectively restore bony orbital volumes and reduce exophthalmos. They have been proven feasible and applicable for reconstructing acute orbital wall fractures.

Authors

Institutions

Publication Details

Journal
Journal of Craniofacial Surgery
Published
2024-09-16
DOI
https://doi.org/10.1097/scs.0000000000010647
Citations
2
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring 3D Printed Implants With Anti-Dropout Function to Overcome Time Constraints in Acute Orbital Fractures for Patient-Specific Implants

Hyoseob Lim, Dong Ha Park, Yeon Kyo Jung, Jun Suk Lee
2 citations
Journal of Craniofacial Surgery
Facial Trauma and Fracture Management
1.15
article

Exploring 3D Printed Implants With Anti-Dropout Function to Overcome Time Constraints in Acute Orbital Fractures for Patient-Specific Implants

Hyoseob Lim, Dong Ha Park, Yeon Kyo Jung, Jun Suk Lee
article en
2 citations

Abstract

Orbital wall reconstruction and implant insertion are crucial procedures for temporarily replacing the orbital walls in cases of significant fractures. Traditional methods using planar orbital implants have faced challenges owing to their flat shape, which increases the risk of dislocation from improper cuts and necessitates the use of screws in the orbital rim. This study aims to improve outcomes by employing customized 3-dimensional implants, thereby reducing complications and risk of dislocation resulting from external shock or implant weight postinsertion. This prospective study included 12 Korean individuals diagnosed with facial fractures (orbital wall injuries). Surgeries were performed on 12 patients, and follow-up CT scans were conducted on 10 of them. Therefore, the authors could only address the results for the 10 patients. The authors used bioactive glass ceramics and medical-grade poly-e-caprolactone to 3D print personalized implants, completing the manufacturing process in an average of 4.6 days. Computed tomography scans guided measurements of orbital volumes and exophthalmos. After surgery, we found that the difference values for bone orbital volumes (<0.1 mL) and exophthalmos (<1 mm except one) decreased compared with presurgery values. Independent t tests and Pearson correlation analysis revealed no significant changes between normal and affected sides in both phases. However, R-values increased in the postsurgery phase. Patients monitored postsurgery at 2 weeks, 3 months, and 6 months showed no complications. The 3D-printed patient-specific implants, customized to individual fracture shapes and featuring distinct implants and locking parts with notches, effectively restore bony orbital volumes and reduce exophthalmos. They have been proven feasible and applicable for reconstructing acute orbital wall fractures.

Journal of Craniofacial SurgeryVol. 35(8)
CITIC Group (China) (CN), Ajou University (KR)
Korea Medical Device Development Fund, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Ministry of Science and ICT, South Korea
Good health and well-being
Openalex Percentile: Top 21%
Facial Trauma and Fracture Management
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.