<i>In Vitro</i> Comparison of Pulsed-Thulium:YAG, Holmium:YAG, and Thulium Fiber Laser
<b><i>Objective:</i></b> To characterize the pulse characteristics and risk of fiber fracture (ROF) of the pulsed-Thulium:YAG (p-Tm:YAG) laser and to compare its ablation volumes (AVs) against Holmium:Yttrium-Aluminium-Garnet (Ho:YAG) laser and Thulium fiber laser (TFL). <b><i>Materials and Methods:</i></b> p-Tm:YAG (100 W-Thulio, Dornier-Medtech<sup>©</sup>, Germany) was characterized using single-use 272 μm core-diameter-fibers. p-Tm:YAG characterization included pulse shape, duration, and peak power (PP) studies. ROF was assessed after 5 minutes of continuous laser activation (CLA) at five decreasing fiber bend radii (1, 0.9, 0.75, 0.6, and 0.45 cm). p-Tm:YAG, Ho:YAG (120 W-Cyber-Ho, Quanta<sup>®</sup>, USA), and TFL (60 W-TFLDrive, Coloplast<sup>®</sup>, Denmark) AVs were compared using a 20-mm linear CLA at 2 mm/second velocity in contact with 20 mm<sup>3</sup> hard stone phantoms (HSP) and soft stone phantoms (SSP) (15:3 and 15:5 water to powder ratio, respectively) fully submerged in saline at 0.5 J-20 Hz or 1 J-10 Hz. After CLA, phantoms underwent three-dimensional (3D) micro-scanning (CT) and subsequent 3D segmentation to estimate the AVs, using 3DSlicer<sup>©</sup>. Each experiment was performed in triplicate. <b><i>Results:</i></b> p-Tm:YAG presents a uniform pulse profile in all of the available preset modes. PP ranged from 564 to 2199 W depending on pulse mode. No laser fiber fracture occurred at any bend radius. p-Tm:YAG achieved similar mean AVs to TFL and Ho:YAG for HSP (8.96 ± 3.1 <i>vs</i> 9.78 ± 1.1 <i>vs</i> 8.8 ± 2.8 mm<sup>3</sup>, <i>p</i> = 0.67) but TFL was associated with higher AVs compared with p-Tm:YAG and Ho:YAG (12.86 ± 1.85 <i>vs</i> 10.12 ± 1.89 <i>vs</i> 7.56 ± 2.21 mm<sup>3</sup>, <i>p</i> = 0.002) against SSP. AVs for HSP increased with pulse energy for p-Tm:YAG and Ho:YAG and (11.56 ± 1.8 <i>vs</i> 6.36 ± 0.84 mm<sup>3</sup> and 11.27 ± 1.98 <i>vs</i> 6.34 ± 0.55 mm<sup>3</sup>, <i>p</i> = 0.03 and <i>p</i> = 0.02), whereas AVs for SSP were similar across laser settings for all laser sources. AVs with TFL were similar across laser settings for both phantom types. <b><i>Conclusion:</i></b> p-Tm:YAG combines intermediate PP between Ho:YAG and TFL, a uniform pulse profile, no ROF with increasing deflection and effective ablation rates. Further clinical studies are needed to confirm these <i>in vitro</i> results.
Authors
- M. Chicaud (ORCID: https://orcid.org/0009-0008-8759-4652)
- Luigi Candela (ORCID: https://orcid.org/0000-0002-0593-8802)
- Daron Smith (ORCID: https://orcid.org/0000-0001-8314-4795)
- Catalina Solano (ORCID: https://orcid.org/0000-0002-4088-1848)
- Mariela Corrales (ORCID: https://orcid.org/0000-0002-1461-8464)
- S. Kutchukian (ORCID: https://orcid.org/0000-0002-5411-6274)
- Olivier Traxer (ORCID: https://orcid.org/0000-0002-2459-3803)
- Frédéric Panthier (ORCID: https://orcid.org/0000-0003-3055-2984)
- Laurent Berthe (ORCID: https://orcid.org/0000-0002-9978-9843)
- Steeve Doizi (ORCID: https://orcid.org/0000-0002-7700-5622)
Institutions
- Centre National de la Recherche Scientifique (FR)
- Vita-Salute San Raffaele University (IT)
- Arts et Métiers (FR)
- Mile End Hospital (GB)
- Université de Poitiers (FR)
- Sorbonne Université (FR)
- Assistance Publique – Hôpitaux de Paris (FR)
- Municipality of Medellín (CO)
- Centre Hospitalier Universitaire de Limoges (FR)
- University College Hospital at Westmoreland Street (GB)
- IRCCS Ospedale San Raffaele (IT)
- Endourological Society (NL)
- Hôpital Tenon (FR)
- Analyse, Recherche, Développement et Evaluation en Endourologie et Lithiase Urinaire (FR)
- University College London (GB)
Publication Details
- Journal
- Journal of Endourology
- Published
- 2024-09-16
- DOI
- https://doi.org/10.1089/end.2024.0424
- Citations
- 17
- Primary Topic
- Laser Applications in Dentistry and Medicine
- Type
- article
- Field-Weighted Citation Impact