Development of Ocular Muscle Stimulation Systems and Optimization of Electrical Stimulus Parameters for Paralytic Strabismus Treatment

Paralysis of the extraocular muscles can lead to complications such as strabismus, diplopia, and loss of stereopsis. Current surgical treatments aim to mitigate these issues by resecting the paralyzed muscle or transposing the other recti muscles to the paralyzed muscle, but they do not fully improve the patient's quality of life. Electrical stimulation shows promise, while requiring further in vivo experiments and research on various stimulation parameters. In this study, we conducted experiments on rabbits to stimulate the superior rectus (SR) muscles using different parameters and stimulation waveforms. To provide various types of electrical stimulation, we developed the ocular muscle stimulation systems capable of both current controlled stimulation (CCS) and high-frequency stimulation (HFS), along with the chip that enables energy-efficient and safe switched-capacitor stimulation (SCS). We also developed electrodes for easy implantation and employed safe and efficient stimulation methods including CCS, SCS, and HFS. The in vivo animal experiments on normal and paralyzed SR muscles of rabbits showed that eyeball abduction angles were proportional to the current and pulse width of the stimulation. With the decaying exponential stimuli of the SCS system, eyeball abductions were 2.58× and 5.65× larger for normal and paralyzed muscles, respectively, compared to the rectangular stimulus of CCS. HFS achieved 0.92× and 0.26× abduction for normal and paralyzed muscles, respectively, with half energy compared to CCS. In addition, the continuous changes in eyeball abduction angle in response to varying stimulation intensity over time were observed.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Engineering
Published
2024-09-16
DOI
https://doi.org/10.1109/tbme.2024.3460814
Citations
2
Primary Topic
Transcranial Magnetic Stimulation Studies
Type
article
Field-Weighted Citation Impact
0.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Ocular Muscle Stimulation Systems and Optimization of Electrical Stimulus Parameters for Paralytic Strabismus Treatment

Han-Sol Lee, Young-Woo Suh, Hyung‐Min Lee, Jong Chan Choe et al.
2 citations
IEEE Transactions on Biomedical Engineering
Transcranial Magnetic Stimulation Studies
0.49
article

Development of Ocular Muscle Stimulation Systems and Optimization of Electrical Stimulus Parameters for Paralytic Strabismus Treatment

Han-Sol Lee, Young-Woo Suh, Hyung‐Min Lee, Jong Chan Choe, Seung Min Yang, Kyeongho Eom, Suk‐Won Hwang, Minju Park
article en
2 citations

Abstract

Paralysis of the extraocular muscles can lead to complications such as strabismus, diplopia, and loss of stereopsis. Current surgical treatments aim to mitigate these issues by resecting the paralyzed muscle or transposing the other recti muscles to the paralyzed muscle, but they do not fully improve the patient's quality of life. Electrical stimulation shows promise, while requiring further in vivo experiments and research on various stimulation parameters. In this study, we conducted experiments on rabbits to stimulate the superior rectus (SR) muscles using different parameters and stimulation waveforms. To provide various types of electrical stimulation, we developed the ocular muscle stimulation systems capable of both current controlled stimulation (CCS) and high-frequency stimulation (HFS), along with the chip that enables energy-efficient and safe switched-capacitor stimulation (SCS). We also developed electrodes for easy implantation and employed safe and efficient stimulation methods including CCS, SCS, and HFS. The in vivo animal experiments on normal and paralyzed SR muscles of rabbits showed that eyeball abduction angles were proportional to the current and pulse width of the stimulation. With the decaying exponential stimuli of the SCS system, eyeball abductions were 2.58× and 5.65× larger for normal and paralyzed muscles, respectively, compared to the rectangular stimulus of CCS. HFS achieved 0.92× and 0.26× abduction for normal and paralyzed muscles, respectively, with half energy compared to CCS. In addition, the continuous changes in eyeball abduction angle in response to varying stimulation intensity over time were observed.

IEEE Transactions on Biomedical EngineeringVol. 72(2)
Korea University (KR), Ansan University (KR)
Affordable and clean energy
Openalex Percentile: Top 34%
Transcranial Magnetic Stimulation Studies
0.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.