<i>Ex situ</i> calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350-352 nm), stimulated Raman scattering (430-760 nm), and plasma emission at half the laser frequency (695-735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive [Skupsky et al., Phys. Plasmas 11, 2763 (2004)] experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10-7 and (1.96 ± 0.11) × 10-7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. This decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-09-01
DOI
https://doi.org/10.1063/5.0218987
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

J. E. Hernández, N. Lemos, J. Katz, S. P. Regan et al.
Review of Scientific Instruments
Laser-Plasma Interactions and Diagnostics
article

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

J. E. Hernández, N. Lemos, J. Katz, S. P. Regan, M. J. Rosenberg, J. Fornes, L. Ceurvorst, Ricky Sommers, George F. Swadling, J. McCumber, Eleanor Tubman, Steven Kostick, J. S. Ross, W. Theobald, T. Filkins, James M. Heinmiller, F. Grullon, P. B. Radha, Patrick Hillyard
article en

Abstract

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350-352 nm), stimulated Raman scattering (430-760 nm), and plasma emission at half the laser frequency (695-735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive [Skupsky et al., Phys. Plasmas 11, 2763 (2004)] experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10-7 and (1.96 ± 0.11) × 10-7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. This decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

Review of Scientific InstrumentsVol. 95(9)
Lawrence Livermore National Laboratory (US), Energetics (United States) (US), Nevada National Security Site (US), Focus (Germany) (DE), University of Rochester (US)
New York State Energy Research and Development Authority
Affordable and clean energy
Openalex Percentile: Top 96%
Laser-Plasma Interactions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.