Comparison of the deformity reduction device (DRD) mini and the Slocum jig in the precision of torsional correction during distal femoral osteotomies in small to medium breed dogs

Previous studies have compared the use of the Slocum- jig to the deformity reduction device (DRD) jig for the correction of distal femoral deformities of varying degrees in the frontal plane. The objective of the current study is to further investigate the use of the mini DRD jig in comparison to the Slocum jig for correction of varying degrees of torsional deformities of the distal femur. Femoral models (n = 60) were developed based on a CT scan of an approximately 16.5 kg normal canine femur. Models were created with a standard varus deformity of 15 degrees, and external torsional deformities of 15, 20, or 30 degrees. Using center of rotation of angulation (CORA) methodology, corrective osteotomies were planned and performed on each of the 3D printed models based on the group assigned. Modeling clay was applied the proximal femur to mimic visualization of a routine lateral surgical approach, while retaining the ability to palpate surgical landmarks. Post-correction anatomic lateral distal femoral angle (aLDFA) and femoral torsion angle (FTA) were measured and recorded. The mean post-correction FTA of groups using the DRD jig for correction were consistently closer to the ideal value compared to those using the Slocum jig, although these differences were not always statistically significant. Correction of external torsion between the DRD jig and the Slocum jig was significantly different in groups 1 and 2 (P = 0.026 and P = 0.046), but not in group 3. For the correction of varus deformity, no significant difference was found between the two jig types in any group. Results of this study suggest jig selection during distal femoral osteotomy for correction of torsional deformity may result in varying precision of post-correction alignment. Clinical significance of this variance remains unclear, and intra-operative visual assessment of alignment should be implemented to guide corrections.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-09-16
DOI
https://doi.org/10.1371/journal.pone.0308764
Primary Topic
Veterinary Orthopedics and Neurology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the deformity reduction device (DRD) mini and the Slocum jig in the precision of torsional correction during distal femoral osteotomies in small to medium breed dogs

Adrien‐Maxence Hespel, Xiaojuan Zhu, Cássio Ricardo Auada Ferrigno, Stephanie K Steuri
PLoS ONE
Veterinary Orthopedics and Neurology
article

Comparison of the deformity reduction device (DRD) mini and the Slocum jig in the precision of torsional correction during distal femoral osteotomies in small to medium breed dogs

Adrien‐Maxence Hespel, Xiaojuan Zhu, Cássio Ricardo Auada Ferrigno, Stephanie K Steuri
article en

Abstract

Previous studies have compared the use of the Slocum- jig to the deformity reduction device (DRD) jig for the correction of distal femoral deformities of varying degrees in the frontal plane. The objective of the current study is to further investigate the use of the mini DRD jig in comparison to the Slocum jig for correction of varying degrees of torsional deformities of the distal femur. Femoral models (n = 60) were developed based on a CT scan of an approximately 16.5 kg normal canine femur. Models were created with a standard varus deformity of 15 degrees, and external torsional deformities of 15, 20, or 30 degrees. Using center of rotation of angulation (CORA) methodology, corrective osteotomies were planned and performed on each of the 3D printed models based on the group assigned. Modeling clay was applied the proximal femur to mimic visualization of a routine lateral surgical approach, while retaining the ability to palpate surgical landmarks. Post-correction anatomic lateral distal femoral angle (aLDFA) and femoral torsion angle (FTA) were measured and recorded. The mean post-correction FTA of groups using the DRD jig for correction were consistently closer to the ideal value compared to those using the Slocum jig, although these differences were not always statistically significant. Correction of external torsion between the DRD jig and the Slocum jig was significantly different in groups 1 and 2 (P = 0.026 and P = 0.046), but not in group 3. For the correction of varus deformity, no significant difference was found between the two jig types in any group. Results of this study suggest jig selection during distal femoral osteotomy for correction of torsional deformity may result in varying precision of post-correction alignment. Clinical significance of this variance remains unclear, and intra-operative visual assessment of alignment should be implemented to guide corrections.

PLoS ONEVol. 19(9)
Western Australian Museum (AU), University of Tennessee at Knoxville (US)
Openalex Percentile: Top 82%
Veterinary Orthopedics and Neurology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.