Development of a Real-Time Radiation Exposure Estimation Method Using a Depth Camera for Radiation Protection Education

X-ray fluoroscopy causes relatively high radiation exposure to physicians, radiation professionals, and patients. Understanding the behavior of scattered radiation is crucial for reducing occupational exposure. We developed a system for estimating radiation exposure during fluoroscopy by monitoring the position of the physician using a depth camera for radiation protection education. The dose distribution of scattered radiation in an X-ray room was simulated using Monte Carlo code. The data were displayed using augmented reality markers, and the dose at each joint point location was estimated using body tracking. Additional functions were created, such as displaying arbitrary two-dimensional cross-sections. The system performance ranged from 9.0 to 11.0 FPS with or without motion and a protective apron. The estimated doses were 0.93 to 1.21 times the measured doses for all joint points, except for the chest and pelvis. The estimated doses for the chest and pelvis were lower than the measured dose, with the minimum values being 0.72 and 0.60 times lower for the chest and pelvis, respectively. The system provides valuable insight into the estimation of radiation dose at joint points based on the physician’s position and movements, the physician’s optimal fluoroscopy location, and warning of dangerous exposure doses.

Authors

Institutions

Publication Details

Journal
Radiation
Published
2024-09-15
DOI
https://doi.org/10.3390/radiation4030021
Citations
4
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.62
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Real-Time Radiation Exposure Estimation Method Using a Depth Camera for Radiation Protection Education

Toshioh Fujibuchi, Choirul Anam, Hiroyuki Arakawa
4 citations
Radiation
Radiation Dose and Imaging
1.62
article

Development of a Real-Time Radiation Exposure Estimation Method Using a Depth Camera for Radiation Protection Education

Toshioh Fujibuchi, Choirul Anam, Hiroyuki Arakawa
article en
4 citations

Abstract

X-ray fluoroscopy causes relatively high radiation exposure to physicians, radiation professionals, and patients. Understanding the behavior of scattered radiation is crucial for reducing occupational exposure. We developed a system for estimating radiation exposure during fluoroscopy by monitoring the position of the physician using a depth camera for radiation protection education. The dose distribution of scattered radiation in an X-ray room was simulated using Monte Carlo code. The data were displayed using augmented reality markers, and the dose at each joint point location was estimated using body tracking. Additional functions were created, such as displaying arbitrary two-dimensional cross-sections. The system performance ranged from 9.0 to 11.0 FPS with or without motion and a protective apron. The estimated doses were 0.93 to 1.21 times the measured doses for all joint points, except for the chest and pelvis. The estimated doses for the chest and pelvis were lower than the measured dose, with the minimum values being 0.72 and 0.60 times lower for the chest and pelvis, respectively. The system provides valuable insight into the estimation of radiation dose at joint points based on the physician’s position and movements, the physician’s optimal fluoroscopy location, and warning of dangerous exposure doses.

RadiationVol. 4(3)
Diponegoro University (ID), Kyushu University (JP)
Openalex Percentile: Top 16%
Radiation Dose and Imaging
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.