Computational Shape Design Optimization of Femoral Implants: Towards Efficient Forging Manufacturing

Total hip replacement is one of the most successful orthopedic operations in modern times. Osteolysis of the femur bone results in implant loosening and failure due to improper loading. To reduce induced stress, enhance load transfer, and minimize stress, the use of Ti-6Al-4V alloy in bone implants was investigated. The objective of this study was to perform a three-dimensional finite element analysis (FEA) of the femoral stem to optimize its shape and analyze the developed deformations and stresses under operational loads. In addition, the challenges associated with the manufacturing optimization of the femoral stem using large strain-based finite element modeling were addressed. The numerical findings showed that the optimized femoral stem using Ti-6Al-4V alloy under the normal daily activities of a person presented a strains distribution that promote uniform load transfer from the proximal to the distal area, and provided a mass reduction of 26%. The stress distribution was found to range from 700 to 0.2 MPa in the critical neck area of the implant. The developed computational tool allows for improved customized designs that lower the risk of prosthesis loss due to stress shielding.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-09-14
DOI
https://doi.org/10.3390/app14188289
Citations
10
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
5.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational Shape Design Optimization of Femoral Implants: Towards Efficient Forging Manufacturing

Rodrigo Valle, Víctor Tuninetti, Brahim Menacer, Diego J. Celentano et al.
10 citations
Applied Sciences
Orthopaedic implants and arthroplasty
5.73
article

Computational Shape Design Optimization of Femoral Implants: Towards Efficient Forging Manufacturing

Rodrigo Valle, Víctor Tuninetti, Brahim Menacer, Diego J. Celentano, Gonzalo Pincheira, César Garrido, Claudio García‐Herrera, Ángelo Oñate, Sunny Narayan, Geovanni Fuentes
article en
10 citations

Abstract

Total hip replacement is one of the most successful orthopedic operations in modern times. Osteolysis of the femur bone results in implant loosening and failure due to improper loading. To reduce induced stress, enhance load transfer, and minimize stress, the use of Ti-6Al-4V alloy in bone implants was investigated. The objective of this study was to perform a three-dimensional finite element analysis (FEA) of the femoral stem to optimize its shape and analyze the developed deformations and stresses under operational loads. In addition, the challenges associated with the manufacturing optimization of the femoral stem using large strain-based finite element modeling were addressed. The numerical findings showed that the optimized femoral stem using Ti-6Al-4V alloy under the normal daily activities of a person presented a strains distribution that promote uniform load transfer from the proximal to the distal area, and provided a mass reduction of 26%. The stress distribution was found to range from 700 to 0.2 MPa in the critical neck area of the implant. The developed computational tool allows for improved customized designs that lower the risk of prosthesis loss due to stress shielding.

Applied SciencesVol. 14(18)
Universidad de Santiago de Chile (CL), Universidad de La Frontera (CL), University of Talca (CL), Pontificia Universidad Católica de Chile (CL), University of Concepción (CL), University of Bío-Bío (CL), Universidad Bernardo O'Higgins (CL), École Nationale Polytechnique d'Oran (DZ), Ecole Supérieure en Génie Electrique et Energétique d'Oran, Tecnológico de Monterrey (MX)
Openalex Percentile: Top 3%
Orthopaedic implants and arthroplasty
5.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.