Application of Surge Arrester in Limiting Voltage Stress at Direct Current Breaker

Hybrid DC circuit breakers combine mechanical switches with a redirecting current path, typically controlled by power electronic devices, to prevent arcing during switch contact separation. The authors’ past work includes a bipolar hybrid DC circuit breaker that effectively redirects the fault current and returns it to the source. This reduces arcing between the mechanical breaker’s contacts and prevents large voltage overshoots across them. However, the breaker’s performance declines as the upstream line inductance increases, causing overvoltage. This work introduces a modification to the originally proposed hybrid DC breaker to make it suitable to use anywhere along DC grid lines. By using a switch-controlled surge arrester in parallel with the DC breaker, part of the arc energy is dissipated in the surge arrester, preventing an overvoltage across the mechanical switches. Based on the experimental results, the proposed method can effectively interrupt the fault current with minimal arcing and reduce the voltage stress across the mechanical switches. To address practical fault currents, tests at high fault currents (900 A) and voltage levels (500 V) are conducted and compared with simulation models and analytical studies. Furthermore, the application of the breaker for the protection of DC distribution grids is illustrated through simulations, and the procedure for designing the breaker components is explained.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-09-15
DOI
https://doi.org/10.3390/app14188319
Citations
2
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Surge Arrester in Limiting Voltage Stress at Direct Current Breaker

Mohammadamin Moghbeli, Sudipta Sen, Shahab Mehraeen
2 citations
Applied Sciences
HVDC Systems and Fault Protection
0.42
article

Application of Surge Arrester in Limiting Voltage Stress at Direct Current Breaker

Mohammadamin Moghbeli, Sudipta Sen, Shahab Mehraeen
article en
2 citations

Abstract

Hybrid DC circuit breakers combine mechanical switches with a redirecting current path, typically controlled by power electronic devices, to prevent arcing during switch contact separation. The authors’ past work includes a bipolar hybrid DC circuit breaker that effectively redirects the fault current and returns it to the source. This reduces arcing between the mechanical breaker’s contacts and prevents large voltage overshoots across them. However, the breaker’s performance declines as the upstream line inductance increases, causing overvoltage. This work introduces a modification to the originally proposed hybrid DC breaker to make it suitable to use anywhere along DC grid lines. By using a switch-controlled surge arrester in parallel with the DC breaker, part of the arc energy is dissipated in the surge arrester, preventing an overvoltage across the mechanical switches. Based on the experimental results, the proposed method can effectively interrupt the fault current with minimal arcing and reduce the voltage stress across the mechanical switches. To address practical fault currents, tests at high fault currents (900 A) and voltage levels (500 V) are conducted and compared with simulation models and analytical studies. Furthermore, the application of the breaker for the protection of DC distribution grids is illustrated through simulations, and the procedure for designing the breaker components is explained.

Applied SciencesVol. 14(18)
Louisiana State University (US)
Openalex Percentile: Top 38%
HVDC Systems and Fault Protection
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.