Achieving Single-Electron Sensitivity at Enhanced Speed in Fully Depleted CCDs with Double-Gate MOSFETs

We introduce a new output amplifier for fully depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating readout noise of 0.74 e_{rms}^{-}/pix in one pixel charge measurement. We have also demonstrated the nondestructive readout capability of the device. Single-electron and single-photon per pixel counting in the entire CCD pixel array has been made possible through the averaging of ten samples, achieving 0.15 e_{rms}^{-}/pix in a pixel readout time of 2.74 ms. We have demonstrated fully depleted CCD readout with better performance than the floating diffusion and floating gate amplifiers available today, in both single and multisampling regimes, boasting at least 6 times the speed of floating gate amplifiers.

Authors

Institutions

Publication Details

Journal
Physical Review Letters
Published
2024-09-17
DOI
https://doi.org/10.1103/physrevlett.133.121003
Citations
5
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Achieving Single-Electron Sensitivity at Enhanced Speed in Fully Depleted CCDs with Double-Gate MOSFETs

Miguel Sofo-Haro, S. Holland, Farah Fahim, Kevan Donlon et al.
5 citations
Physical Review Letters
CCD and CMOS Imaging Sensors
1.04
article

Achieving Single-Electron Sensitivity at Enhanced Speed in Fully Depleted CCDs with Double-Gate MOSFETs

Miguel Sofo-Haro, S. Holland, Farah Fahim, Kevan Donlon, J. Estrada, C. W. Leitz
article en
5 citations

Abstract

We introduce a new output amplifier for fully depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating readout noise of 0.74 e_{rms}^{-}/pix in one pixel charge measurement. We have also demonstrated the nondestructive readout capability of the device. Single-electron and single-photon per pixel counting in the entire CCD pixel array has been made possible through the averaging of ten samples, achieving 0.15 e_{rms}^{-}/pix in a pixel readout time of 2.74 ms. We have demonstrated fully depleted CCD readout with better performance than the floating diffusion and floating gate amplifiers available today, in both single and multisampling regimes, boasting at least 6 times the speed of floating gate amplifiers.

Physical Review LettersVol. 133(12)
Fermi National Accelerator Laboratory (US), Lawrence Berkeley National Laboratory (US), Universidad Nacional de Córdoba (AR), MIT Lincoln Laboratory (US)
Affordable and clean energy
Openalex Percentile: Top 23%
CCD and CMOS Imaging Sensors
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.