CHARACTERIZATION AND ELECTROCHEMICAL BEHAVIOUR OF BORON DOPED DIAMOND IN DETECTING AMODIAQUINE

Amodiaquine (AQ) is an essential medicine in treating malaria. Yet, the threat of drug resistance and toxicity necessitates accurate measurement of AQ in the human body. This research determines the amodiaquine (AQ) detection performance of boron-doped diamond (BDD) working electrodes. The study utilizes different pulse velocity (DPV) methods to analyze the AQ reaction behavior of BDD. The research demonstrates the reaction mechanism: Two electrons are transferred, and irreversible oxidation reactions occur. The sensor limit of detection (LOD) is measured to determine the performance of working electrodes for AQ detection. The LOD is calculated between 0.0645 µM and 0.3 µM, and changes in analytical concentrations relative to maximum current are calculated. The LOD of the BDD electrode is 1.5×10–8 M, lower than previous research on AQ sensors, showing the effectivity of the BDD electrode as an AQ sensor.

Authors

Institutions

Publication Details

Journal
Indonesian Physical Review
Published
2024-09-17
DOI
https://doi.org/10.29303/ipr.v7i3.345
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CHARACTERIZATION AND ELECTROCHEMICAL BEHAVIOUR OF BORON DOPED DIAMOND IN DETECTING AMODIAQUINE

Yunita Triana, Jatmoko Awali, Hizkia Alpha Dewanto, Murni Handayani et al.
Indonesian Physical Review
Electrochemical sensors and biosensors
article

CHARACTERIZATION AND ELECTROCHEMICAL BEHAVIOUR OF BORON DOPED DIAMOND IN DETECTING AMODIAQUINE

Yunita Triana, Jatmoko Awali, Hizkia Alpha Dewanto, Murni Handayani, Irsyad Al Habib, Najwa Nabila, Keysi Devain Destiny, Fadli Hizam
article en

Abstract

Amodiaquine (AQ) is an essential medicine in treating malaria. Yet, the threat of drug resistance and toxicity necessitates accurate measurement of AQ in the human body. This research determines the amodiaquine (AQ) detection performance of boron-doped diamond (BDD) working electrodes. The study utilizes different pulse velocity (DPV) methods to analyze the AQ reaction behavior of BDD. The research demonstrates the reaction mechanism: Two electrons are transferred, and irreversible oxidation reactions occur. The sensor limit of detection (LOD) is measured to determine the performance of working electrodes for AQ detection. The LOD is calculated between 0.0645 µM and 0.3 µM, and changes in analytical concentrations relative to maximum current are calculated. The LOD of the BDD electrode is 1.5×10–8 M, lower than previous research on AQ sensors, showing the effectivity of the BDD electrode as an AQ sensor.

Indonesian Physical ReviewVol. 7(3)
Institut Teknologi Kalimantan (ID), National Research, Development and Innovation Office (HU), National Research and Innovation Agency (ID)
Institut Teknologi Kalimantan, Keio University
Openalex Percentile: Top 87%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

CHARACTERIZATION AND ELECTROCHEMICAL BEHAVIOUR OF BORON DOPED DIAMOND IN DETECTING AMODIAQUINE — Yunita Triana, Jatmoko Awali, et al. · Indonesian Physical Review (2024) | TGRS Research Map | TGRS