Treatment of domestic wastewater and extracellular polymeric substance accumulation in siphon‐type composite vertical subsurface flow constructed wetland

In this study, the siphon-type composite vertical flow constructed wetland (Sc-VSsFCW) was constructed with anthracite and shale ceramsite chosen as the substrate bed materials. During the 90-day experiment, typical pollutant removal effects of wastewater and extracellular polymeric substance (EPS) accumulation were investigated. Meanwhile, X-ray diffraction and scanning electron microscopy were used to examine the phase composition and surface morphology to analyze adsorptive property. Additionally, we evaluated the impact of siphon effluent on clogging and depolymerization by measuring the EPS components' evolution within the system. The findings reveal that both the anthracite and shale ceramsite systems exhibit impressive removal efficiencies for total phosphorus (TP), total dissolved phosphorus (TDP), soluble reactive phosphorus (SRP), chemical oxygen demand (COD), ammonium nitrogen (NH<sub>4</sub> <sup>+</sup>-N), and nitrate nitrogen (NO<sub>3</sub> <sup>-</sup>-N). However, as the experiment progressed, TP removal rates in both systems gradually declined because of the saturation of adsorption sites on the substrate surfaces. Although the dissolved oxygen (DO) levels remained relatively stable throughout the experiment, pH exhibited distinct patterns, suggesting that the anthracite system relies primarily on chemical adsorption, whereas the shale ceramsite system predominantly utilizes physical adsorption. After an initial period of fluctuation, the permeability coefficient and porosity of the system gradually stabilized, and the protein and polysaccharide contents in both systems exhibited a downward trend. The study underscores that anthracite and shale ceramsite have good effectiveness in pollutant removal as substrate materials. Overall, the hydraulic conditions of the double repeated oxygen coupling siphon in the Sc-VSsFCW system contribute to enhanced re-oxygenation capacity and permeability coefficient during operation. The changes in EPS content indicate that the siphon effluent exerts a certain depolymerization effect on the EPS within the system, thereby mitigating the risk of biological clogging to a certain extent. PRACTITIONER POINTS: The system can still maintain good pollutant treatment effect in long-term operation. The re-oxygenation method of the system can achieve efficient and long-term re-oxygenation effect. The siphon effluent has a certain improvement effect on the permeability coefficient and porosity, but it cannot effectively inhibit the occurrence of clogging. The EPS content did not change significantly during the operation of the system, and there was a risk of biological clogging.

Authors

Institutions

Publication Details

Journal
Water Environment Research
Published
2024-09-01
DOI
https://doi.org/10.1002/wer.11132
Citations
1
Primary Topic
Constructed Wetlands for Wastewater Treatment
Type
article
Field-Weighted Citation Impact
0.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Treatment of domestic wastewater and extracellular polymeric substance accumulation in siphon‐type composite vertical subsurface flow constructed wetland

Lin Qiu, Yong Liu, Fahui Nie, Wenping Cao et al.
1 citations
Water Environment Research
Constructed Wetlands for Wastewater Treatment
0.29
article

Treatment of domestic wastewater and extracellular polymeric substance accumulation in siphon‐type composite vertical subsurface flow constructed wetland

Lin Qiu, Yong Liu, Fahui Nie, Wenping Cao, Hao Wu, Cheng Jiang
article en
1 citations

Abstract

In this study, the siphon-type composite vertical flow constructed wetland (Sc-VSsFCW) was constructed with anthracite and shale ceramsite chosen as the substrate bed materials. During the 90-day experiment, typical pollutant removal effects of wastewater and extracellular polymeric substance (EPS) accumulation were investigated. Meanwhile, X-ray diffraction and scanning electron microscopy were used to examine the phase composition and surface morphology to analyze adsorptive property. Additionally, we evaluated the impact of siphon effluent on clogging and depolymerization by measuring the EPS components' evolution within the system. The findings reveal that both the anthracite and shale ceramsite systems exhibit impressive removal efficiencies for total phosphorus (TP), total dissolved phosphorus (TDP), soluble reactive phosphorus (SRP), chemical oxygen demand (COD), ammonium nitrogen (NH<sub>4</sub> <sup>+</sup>-N), and nitrate nitrogen (NO<sub>3</sub> <sup>-</sup>-N). However, as the experiment progressed, TP removal rates in both systems gradually declined because of the saturation of adsorption sites on the substrate surfaces. Although the dissolved oxygen (DO) levels remained relatively stable throughout the experiment, pH exhibited distinct patterns, suggesting that the anthracite system relies primarily on chemical adsorption, whereas the shale ceramsite system predominantly utilizes physical adsorption. After an initial period of fluctuation, the permeability coefficient and porosity of the system gradually stabilized, and the protein and polysaccharide contents in both systems exhibited a downward trend. The study underscores that anthracite and shale ceramsite have good effectiveness in pollutant removal as substrate materials. Overall, the hydraulic conditions of the double repeated oxygen coupling siphon in the Sc-VSsFCW system contribute to enhanced re-oxygenation capacity and permeability coefficient during operation. The changes in EPS content indicate that the siphon effluent exerts a certain depolymerization effect on the EPS within the system, thereby mitigating the risk of biological clogging to a certain extent. PRACTITIONER POINTS: The system can still maintain good pollutant treatment effect in long-term operation. The re-oxygenation method of the system can achieve efficient and long-term re-oxygenation effect. The siphon effluent has a certain improvement effect on the permeability coefficient and porosity, but it cannot effectively inhibit the occurrence of clogging. The EPS content did not change significantly during the operation of the system, and there was a risk of biological clogging.

Water Environment ResearchVol. 96(9)
East China Jiaotong University (CN), Masteel (China) (CN), Jiangxi Academy of Sciences (CN)
Clean water and sanitation
Openalex Percentile: Top 39%
Constructed Wetlands for Wastewater Treatment
0.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.