Wide-Sensing-Ranged PANI:PEO Piezoresistive Pressure Sensor Array in Pressure Distribution Monitoring on Cervical Disks Under Neck Flexion

Recently, phubbing has led to a significant increase in neck-related diseases such as cervical disk (CVD) herniation. CVDs experience a typical pressure of approximately 200 kPa in the upright position, which increases dramatically with the degrees of flexion. Thus, there is a high probability for patients who have undergone the cervical artificial disk replacement surgery to have the revision surgery owing to inappropriate postures. Herein, a highly sensitive piezoresistive pressure sensor array with a wide sensing range of up to 1000 kPa, using polyethylene oxide (PEO) as the sensing membrane and polyaniline (PANI) as the conductive filler, is proposed to real-time monitor the pressure distribution on CVDs. The optimal PANI doping concentration in PANI:PEO composite films was determined to be 0.1%, which demonstrated excellent sensitivity of 0.279 kPa<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>, a high coefficient of determination (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${R} ^{{2}}$ </tex-math></inline-formula>) of 0.959, and a short relaxation time of 0.72 s of the PANI:PEO piezoresistive pressure sensors. To accommodate the sensor array within the limited space of the cervical vertebrae, the electrode size of the devices was significantly reduced to less than <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$100~\mu $ </tex-math></inline-formula>m to realize a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2\times 3$ </tex-math></inline-formula> PANI:PEO piezoresistive pressure sensor array. The fabricated pressure sensor array effectively monitored the pressure distribution on CVDs in a cervical spine model with a full cervical spine and dual cervical vertebrae under different flexion angles, holding favorable potential to avoid further CVD herniation after the cervical artificial disk replacement surgery.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-09-17
DOI
https://doi.org/10.1109/jsen.2024.3457991
Citations
4
Primary Topic
Tribology and Lubrication Engineering
Type
article
Field-Weighted Citation Impact
0.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wide-Sensing-Ranged PANI:PEO Piezoresistive Pressure Sensor Array in Pressure Distribution Monitoring on Cervical Disks Under Neck Flexion

Tzu-Chuan Yang, Jyh‐Wei Lee, Jer‐Chyi Wang, Han‐Hsiang Tai et al.
4 citations
IEEE Sensors Journal
Tribology and Lubrication Engineering
0.85
article

Wide-Sensing-Ranged PANI:PEO Piezoresistive Pressure Sensor Array in Pressure Distribution Monitoring on Cervical Disks Under Neck Flexion

Tzu-Chuan Yang, Jyh‐Wei Lee, Jer‐Chyi Wang, Han‐Hsiang Tai, Yang-Jin Shen, Yu-Jen Lu, Hung‐Chi Chen
article en
4 citations

Abstract

Recently, phubbing has led to a significant increase in neck-related diseases such as cervical disk (CVD) herniation. CVDs experience a typical pressure of approximately 200 kPa in the upright position, which increases dramatically with the degrees of flexion. Thus, there is a high probability for patients who have undergone the cervical artificial disk replacement surgery to have the revision surgery owing to inappropriate postures. Herein, a highly sensitive piezoresistive pressure sensor array with a wide sensing range of up to 1000 kPa, using polyethylene oxide (PEO) as the sensing membrane and polyaniline (PANI) as the conductive filler, is proposed to real-time monitor the pressure distribution on CVDs. The optimal PANI doping concentration in PANI:PEO composite films was determined to be 0.1%, which demonstrated excellent sensitivity of 0.279 kPa<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>, a high coefficient of determination (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${R} ^{{2}}$ </tex-math></inline-formula>) of 0.959, and a short relaxation time of 0.72 s of the PANI:PEO piezoresistive pressure sensors. To accommodate the sensor array within the limited space of the cervical vertebrae, the electrode size of the devices was significantly reduced to less than <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$100~\mu $ </tex-math></inline-formula>m to realize a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2\times 3$ </tex-math></inline-formula> PANI:PEO piezoresistive pressure sensor array. The fabricated pressure sensor array effectively monitored the pressure distribution on CVDs in a cervical spine model with a full cervical spine and dual cervical vertebrae under different flexion angles, holding favorable potential to avoid further CVD herniation after the cervical artificial disk replacement surgery.

IEEE Sensors JournalVol. 24(21)
Ming Chi University of Technology (TW), Chang Gung University (TW), Chang Gung Memorial Hospital (TW)
Chang Gung Memorial Hospital, Linkou, National Science and Technology Council
Affordable and clean energy
Openalex Percentile: Top 31%
Tribology and Lubrication Engineering
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.