Variability Reduction in NIRS Measurements for Reliable TBI Patient Monitoring

Traumatic brain injury (TBI) is a leading cause of mortality and morbidity, commonly causing intracranial hematomas as a serious complication. While computerized tomography (CT) scans are the standard diagnostic tool for hematoma detection, their use for continuous monitoring is limited due to radiation risks and logistical difficulties. Near-infrared spectroscopy (NIRS) offers a noninvasive, portable, and cost-effective alternative, as evidenced by the Infrascanner—the first handheld device proven in clinical studies for hematoma detection. Despite its success in hematoma detection, the Infrascanner’s efficacy in tracking hematoma expansion remains unexplored. Our recent pilot studies with repeated recordings conducted to investigate Infrascanner’s potential as a monitoring device showed large signal variability (SD) even under unchanging or healthy conditions when its original protocols developed for hematoma detection are used. In this work, our primary goal was to develop novel data processing algorithms with a modified data collection regime and evaluate their performance in reducing SD in comparison to each other and the original algorithms. Our results suggested that among the proposed algorithms, the most promising was based on eliminating maximal values from hemispheric measurement pairs, resulting in significantly improved signal stability and overall device performance. Our key contributions in this study involve the development and evaluation of novel data collection and processing methods for the Infrascanner to reduce its SD and false alarm rate (FAR) while improving its sensitivity and correlation with hematoma size, which can further strengthen the potential utility of the Infrascanner in monitoring TBI patients for hematoma expansion.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-09-17
DOI
https://doi.org/10.1109/jsen.2024.3457905
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Variability Reduction in NIRS Measurements for Reliable TBI Patient Monitoring

Joshua Richman, Jan O. Jansen, Lindy Reynolds, Hasan Ayaz et al.
1 citations
IEEE Sensors Journal
Non-Invasive Vital Sign Monitoring
0.18
article

Variability Reduction in NIRS Measurements for Reliable TBI Patient Monitoring

Joshua Richman, Jan O. Jansen, Lindy Reynolds, Hasan Ayaz, Meltem İzzetoğlu, Shannon W. Stephens, Elizabeth Liptrap, Timothy M. Smith, Alex B. Valadka, Baruch Ben-Dor, Jonathan Black, John Bradley Holcomb
article en
1 citations

Abstract

Traumatic brain injury (TBI) is a leading cause of mortality and morbidity, commonly causing intracranial hematomas as a serious complication. While computerized tomography (CT) scans are the standard diagnostic tool for hematoma detection, their use for continuous monitoring is limited due to radiation risks and logistical difficulties. Near-infrared spectroscopy (NIRS) offers a noninvasive, portable, and cost-effective alternative, as evidenced by the Infrascanner—the first handheld device proven in clinical studies for hematoma detection. Despite its success in hematoma detection, the Infrascanner’s efficacy in tracking hematoma expansion remains unexplored. Our recent pilot studies with repeated recordings conducted to investigate Infrascanner’s potential as a monitoring device showed large signal variability (SD) even under unchanging or healthy conditions when its original protocols developed for hematoma detection are used. In this work, our primary goal was to develop novel data processing algorithms with a modified data collection regime and evaluate their performance in reducing SD in comparison to each other and the original algorithms. Our results suggested that among the proposed algorithms, the most promising was based on eliminating maximal values from hemispheric measurement pairs, resulting in significantly improved signal stability and overall device performance. Our key contributions in this study involve the development and evaluation of novel data collection and processing methods for the Infrascanner to reduce its SD and false alarm rate (FAR) while improving its sensitivity and correlation with hematoma size, which can further strengthen the potential utility of the Infrascanner in monitoring TBI patients for hematoma expansion.

IEEE Sensors JournalVol. 24(21)
University of Alabama at Birmingham (US), Southwestern Medical Center (US), Infrascan (United States) (US), Southwestern Medical Center (US), Drexel University (US), Villanova University (US), The University of Texas Southwestern Medical Center (US)
Openalex Percentile: Top 53%
Non-Invasive Vital Sign Monitoring
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.