Spillover Analysis and Mainbeam Characterisation of Arctic Weather Satellite Radiometer Using Method of Moments

The Arctic Weather Satellite (AWS) is a single instrument mission consisting of a microwave sounder operating in the 54, 89, 183 and 325 GHz bands. The optical design of the instrument consists of a feedcluster directly illuminating a crosstrack scanning mirror, keeping the instrument compact. Due to the simple optics, the beams are not co-aligned and none are in the scanning mirror focal point, leading to beam divergence, asymmetry and scan angle dependent variations in spillover. Using Method of Moment (MoM) simulations of the optics as well as instrument structure, the complete farfield sphere of the instrument can be simulated up to 183 GHz. This paper contains detailed analysis of spillover, beam divergence and intercomparison of physical optics, MoM and nearfield antenna measurements for the mainbeam.

Authors

Institutions

Publication Details

Journal
IEEE Open Journal of Antennas and Propagation
Published
2024-09-17
DOI
https://doi.org/10.1109/ojap.2024.3462601
Citations
1
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
1.30
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spillover Analysis and Mainbeam Characterisation of Arctic Weather Satellite Radiometer Using Method of Moments

Kalle Kempe, Alistair Bell, Mustafa Murat Bilgiç, Axel Murk et al.
1 citations
IEEE Open Journal of Antennas and Propagation
Calibration and Measurement Techniques
1.30
article

Spillover Analysis and Mainbeam Characterisation of Arctic Weather Satellite Radiometer Using Method of Moments

Kalle Kempe, Alistair Bell, Mustafa Murat Bilgiç, Axel Murk, Roland Albers
article en
1 citations

Abstract

The Arctic Weather Satellite (AWS) is a single instrument mission consisting of a microwave sounder operating in the 54, 89, 183 and 325 GHz bands. The optical design of the instrument consists of a feedcluster directly illuminating a crosstrack scanning mirror, keeping the instrument compact. Due to the simple optics, the beams are not co-aligned and none are in the scanning mirror focal point, leading to beam divergence, asymmetry and scan angle dependent variations in spillover. Using Method of Moment (MoM) simulations of the optics as well as instrument structure, the complete farfield sphere of the instrument can be simulated up to 183 GHz. This paper contains detailed analysis of spillover, beam divergence and intercomparison of physical optics, MoM and nearfield antenna measurements for the mainbeam.

IEEE Open Journal of Antennas and PropagationVol. 5(6)
University of Bern (CH), Omnisys Instruments (Sweden) (SE)
Climate action
Openalex Percentile: Top 13%
Calibration and Measurement Techniques
1.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.