Fusion neutron source and array of particle detectors for nondestructive interrogation of special nuclear materials

Presented herein are the outcomes of an experimental test involving a pioneering portable-active interrogation system designed for the nondestructive detection of special nuclear materials (SNMs). The system relies on the threshold energy neutron analysis concept and incorporates a portable deuterium–deuterium (DD) neutron generator producing a particle intensity of 5 × 107 n/s, coupled with three arrays of tensioned metastable fluid detectors (TMFDs) to detect secondary neutrons from the fissile material. In the presence of the fissile material, prompt fission neutrons are emitted, with an average energy of approximately 2 MeV, and around 30% of these neutrons have energies above that of the DD neutron source (2.45 MeV). The detection of a statistically significant neutron population exceeding this threshold firmly indicates the presence of SNM. TMFDs exhibit high sensitivity in efficiently detecting neutrons above the threshold while adeptly discriminating against neutrons below the threshold as well as gamma rays. This unique feature allows the interrogation system to maintain a lightweight profile without necessitating substantial shielding materials. The validation experiments involved the placement of 70 or 140 g masses of U-235 within a 1 m3 inspection volume. Measurements were carried out over 30 min intervals, repeated numerous times, both with and without U-235, at a DD neutron source intensity of 8 × 105 n/sec. Experimental count rates with natural uranium (NU) are consistently above those without NU. The probability of detection (PD) and probability of false alarm (PFA) were assessed utilizing these count rates. The DD neutron source intensity and inspection time were normalized at 5 × 107 n/sec and 90 s, respectively. The results indicated a PD of approximately 74% and 98% for detecting 70 and 140 g of U-235, respectively, with a PFA of <5%. These promising outcomes align with the specified PD (>90%) and PFA (<5%) targets outlined in ANSI standards.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physics
Published
2024-09-17
DOI
https://doi.org/10.1063/5.0225179
Citations
2
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
1.22

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fusion neutron source and array of particle detectors for nondestructive interrogation of special nuclear materials

Mahmoud Bakr, Thomas B. Scott, Kai Masuda, Yoshiyuki Takahashi et al.
2 citations
Journal of Applied Physics
Nuclear Physics and Applications
1.22
article

Fusion neutron source and array of particle detectors for nondestructive interrogation of special nuclear materials

Mahmoud Bakr, Thomas B. Scott, Kai Masuda, Yoshiyuki Takahashi, Norio Yamakawa, Tsuyoshi Misawa
article en
2 citations

Abstract

Presented herein are the outcomes of an experimental test involving a pioneering portable-active interrogation system designed for the nondestructive detection of special nuclear materials (SNMs). The system relies on the threshold energy neutron analysis concept and incorporates a portable deuterium–deuterium (DD) neutron generator producing a particle intensity of 5 × 107 n/s, coupled with three arrays of tensioned metastable fluid detectors (TMFDs) to detect secondary neutrons from the fissile material. In the presence of the fissile material, prompt fission neutrons are emitted, with an average energy of approximately 2 MeV, and around 30% of these neutrons have energies above that of the DD neutron source (2.45 MeV). The detection of a statistically significant neutron population exceeding this threshold firmly indicates the presence of SNM. TMFDs exhibit high sensitivity in efficiently detecting neutrons above the threshold while adeptly discriminating against neutrons below the threshold as well as gamma rays. This unique feature allows the interrogation system to maintain a lightweight profile without necessitating substantial shielding materials. The validation experiments involved the placement of 70 or 140 g masses of U-235 within a 1 m3 inspection volume. Measurements were carried out over 30 min intervals, repeated numerous times, both with and without U-235, at a DD neutron source intensity of 8 × 105 n/sec. Experimental count rates with natural uranium (NU) are consistently above those without NU. The probability of detection (PD) and probability of false alarm (PFA) were assessed utilizing these count rates. The DD neutron source intensity and inspection time were normalized at 5 × 107 n/sec and 90 s, respectively. The results indicated a PD of approximately 74% and 98% for detecting 70 and 140 g of U-235, respectively, with a PFA of <5%. These promising outcomes align with the specified PD (>90%) and PFA (<5%) targets outlined in ANSI standards.

Journal of Applied PhysicsVol. 136(11)
Kyoto University (JP), University of Bristol (GB), Assiut University (EG)
Ministry of Economy, Trade and Industry
Peace, Justice and strong institutions
Openalex Percentile: Top 21%
Nuclear Physics and Applications
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.