Numerical modeling of heat losses from hot water storage tank

Domestic hot water storage tanks (HWST) are widely used devices, and their daily operation can generate significant annual heat losses to the environment. Previous studies concerning HWST have mainly focused on the impact of insulation quality and thickness, stratification, and tank operation on total heat losses. Some studies have addressed these losses concerning different parts of the tank, including upper, lower, and side walls. However, the influence of insulating additional tank elements, such as connectors, on heat loss has not been analyzed. Therefore, experimental studies were conducted as a reference for the temperature distribution and heat loss from an insulated HWST equipped with 12 connectors. Then, CFD numerical calculations of heat loss were performed for various variants: an insulated HWST without connectors, a tank with connectors insulated in five different ways, and an uninsulated tank. It was found that, in extreme cases of poor insulation of the tank connectors, the heat loss increased by 92.5 % and 147.6 %, respectively, compared to the reference loss. This means an increase in heat loss streams by 62.0 W and 98.9 W compared to the reference case. The latter value corresponds to an annual heat loss of approximately 3 GJ. The study also showed that insulating the bottom of the tank is crucial. With proper insulation, heat losses from this part account for less than 10 % of the total heat loss. The results highlight the critical role of proper connector insulation in minimizing standby heat losses in water storage systems.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-09-17
DOI
https://doi.org/10.1016/j.csite.2024.105146
Citations
8
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
10.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical modeling of heat losses from hot water storage tank

Mohamed Mami, Robert Junga, Szymon Sobek, M. Kabaciński et al.
8 citations
Case Studies in Thermal Engineering
Spacecraft and Cryogenic Technologies
10.39
article

Numerical modeling of heat losses from hot water storage tank

Mohamed Mami, Robert Junga, Szymon Sobek, M. Kabaciński, Rafał Stanisławski, R. Balicz, Z. Mruk, J. Pospolita
article en
8 citations

Abstract

Domestic hot water storage tanks (HWST) are widely used devices, and their daily operation can generate significant annual heat losses to the environment. Previous studies concerning HWST have mainly focused on the impact of insulation quality and thickness, stratification, and tank operation on total heat losses. Some studies have addressed these losses concerning different parts of the tank, including upper, lower, and side walls. However, the influence of insulating additional tank elements, such as connectors, on heat loss has not been analyzed. Therefore, experimental studies were conducted as a reference for the temperature distribution and heat loss from an insulated HWST equipped with 12 connectors. Then, CFD numerical calculations of heat loss were performed for various variants: an insulated HWST without connectors, a tank with connectors insulated in five different ways, and an uninsulated tank. It was found that, in extreme cases of poor insulation of the tank connectors, the heat loss increased by 92.5 % and 147.6 %, respectively, compared to the reference loss. This means an increase in heat loss streams by 62.0 W and 98.9 W compared to the reference case. The latter value corresponds to an annual heat loss of approximately 3 GJ. The study also showed that insulating the bottom of the tank is crucial. With proper insulation, heat losses from this part account for less than 10 % of the total heat loss. The results highlight the critical role of proper connector insulation in minimizing standby heat losses in water storage systems.

Case Studies in Thermal EngineeringVol. 62
Silesian University of Technology (PL), Opole University of Technology (PL), University of Monastir (TN), University of Opole (PL), Państwowa Wyższa Szkoła Zawodowa w Raciborzu (PL)
Clean water and sanitation
Openalex Percentile: Top 2%
Spacecraft and Cryogenic Technologies
10.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.