Assessment of Conventional X-ray Machine Resolution, Using Designed Phantom

The diagnostics x-ray machine produces electromagnetic radiation used to image the body in case of pathology; therefore, this exposure was justified. But if the exposure parameters were not chosen satisfactorily, imaging has to be repeated where the patient was subjected to a substantial amount of radiation. To determine the spatial resolution in order to find the optimum kV relative to machine type, the phantom is placed on the detector surface, and a uniform source of radiation is placed above the bar phantom, where the focus-to-film distance was 1 m. An image is acquired; the unit was set at 2 mAs and 40 kVp value. In this study, 3 conventional x-ray machines were investigated using point phantom designed by the researcher, which consisted of a variable diameter used to test variable exposure factors. The results showed that the best machine resolution was Toshiba model E7239X (2016) for Modern Medical Center that had a high resolution of 96% at 45 kV for a point of thickness of 1.4 mm.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Engineering
Published
2024-09-17
DOI
https://doi.org/10.1097/jce.0000000000000664
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Conventional X-ray Machine Resolution, Using Designed Phantom

Mohamed Elfadil Mohamed Gar-elnabi, Nedal Abdalaal Abdallhah, Mohamed Yagoub Esmeal
1 links
Journal of Clinical Engineering
Advanced X-ray and CT Imaging
article

Assessment of Conventional X-ray Machine Resolution, Using Designed Phantom

Mohamed Elfadil Mohamed Gar-elnabi, Nedal Abdalaal Abdallhah, Mohamed Yagoub Esmeal
article en

Abstract

The diagnostics x-ray machine produces electromagnetic radiation used to image the body in case of pathology; therefore, this exposure was justified. But if the exposure parameters were not chosen satisfactorily, imaging has to be repeated where the patient was subjected to a substantial amount of radiation. To determine the spatial resolution in order to find the optimum kV relative to machine type, the phantom is placed on the detector surface, and a uniform source of radiation is placed above the bar phantom, where the focus-to-film distance was 1 m. An image is acquired; the unit was set at 2 mAs and 40 kVp value. In this study, 3 conventional x-ray machines were investigated using point phantom designed by the researcher, which consisted of a variable diameter used to test variable exposure factors. The results showed that the best machine resolution was Toshiba model E7239X (2016) for Modern Medical Center that had a high resolution of 96% at 45 kV for a point of thickness of 1.4 mm.

Journal of Clinical EngineeringVol. 49(4)
Center for Assessment (US)
Openalex Percentile: Top 86%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of Conventional X-ray Machine Resolution, Using Designed Phantom — Mohamed Elfadil Mohamed Gar-elnabi, Nedal Abdalaal Abdallhah, et al. · Journal of Clinical Engineering (2024) | TGRS Research Map | TGRS