Modeling of two-element tangential eddy current probe with active shielding for soldered joints inspection
The paper is devoted to designing a finite-element model of the eddy current probe for testing the degree of soldering of lap soldered joints of conductive busbars. The method for finite-element model designing is developed, which parameters provide calculations error of signals of finite-element model of eddy current probe below 1.5%. The test results confirm the performance of the eddy current probe, the measurement range for soldered joints defect size from 0 to 100 % and provision of the declared basic absolute error of the degree of soldering measurement of 5 %.
Authors
- Alexander Gorbunov
- P. V. Solomenchuk
- А. S. Umanskii (ORCID: https://orcid.org/0000-0003-0009-6172)
Institutions
- Saint Petersburg Mining University (RU)
- Constanta Maritime University (RO)
Publication Details
- Journal
- Дефектоскопия
- Published
- 2024-09-16
- DOI
- https://doi.org/10.31857/s0130308224080042
- Primary Topic
- Non-Destructive Testing Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00