Atrial Functional Tricuspid Regurgitation Associated With Atrial Standstill

We report a case of atrial functional tricuspid regurgitation with an atrial standstill in a 71-year-old woman with a history of chronic atrial fibrillation (AF). The ECG showed a flat baseline with no AF waves and regular, narrow QRS complexes, whereas the previous ECG demonstrated AF. Echocardiography revealed dilation of the right atrium and the tricuspid annulus with severe regurgitation, but mitral regurgitation was mild. No atrial contraction was detected. Bilateral ventricular function was preserved. Cardiac catheterization showed no pulmonary hypertension and an a-wave in atrial pressure tracings. During surgery, epicardial pacing was unable to capture both atria. The tricuspid valve was replaced and a pacemaker was implanted.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-09-17
DOI
https://doi.org/10.7759/cureus.69577
Citations
1
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Atrial Functional Tricuspid Regurgitation Associated With Atrial Standstill

Tomokazu Kosuga, Hidetsugu Hori, Keiichiro Tayama, Kenichi Kosuga et al.
1 citations
Cureus
Atrial Fibrillation Management and Outcomes
0.40
article

Atrial Functional Tricuspid Regurgitation Associated With Atrial Standstill

Tomokazu Kosuga, Hidetsugu Hori, Keiichiro Tayama, Kenichi Kosuga, Yukio Hosokawa
article en
1 citations

Abstract

We report a case of atrial functional tricuspid regurgitation with an atrial standstill in a 71-year-old woman with a history of chronic atrial fibrillation (AF). The ECG showed a flat baseline with no AF waves and regular, narrow QRS complexes, whereas the previous ECG demonstrated AF. Echocardiography revealed dilation of the right atrium and the tricuspid annulus with severe regurgitation, but mitral regurgitation was mild. No atrial contraction was detected. Bilateral ventricular function was preserved. Cardiac catheterization showed no pulmonary hypertension and an a-wave in atrial pressure tracings. During surgery, epicardial pacing was unable to capture both atria. The tricuspid valve was replaced and a pacemaker was implanted.

CureusVol. 16(9)
Hospital Muñiz (AR)
Zero hunger
Openalex Percentile: Top 33%
Atrial Fibrillation Management and Outcomes
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.