Use of Melinex film for flat embedding tissue sections in LR White

Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components, and this may necessitate removal of a considerable amount of material from the final resin-embedded tissue block to ensure production of complete sections of the sample. To mitigate this problem, a number of techniques have been devised that ensure the sample is held flat during the final curing/polymerisation of the resin. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin embedding are generally unsuitable. The method describes the preparation and use of air-tight flat-embedding chambers prepared from Melinex film and provides an inexpensive, technically simpler, and versatile alternative to chambers formed from either Thermanox coverslips or Aclar films that have previously been advocated for such purposes. Lay description: Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components. Such distortions may necessitate removal of a considerable amount of material to ensure production of complete sections of the sample. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin flat-embedding are generally unsuitable. Air-tight flat-embedding chambers prepared from either Thermanox coverslips, or a combination of PTFE-coated glass slides, polycarbonate film gaskets, and Aclar film have been advocated for such purposes. Thermanox coverslips are expensive and limited in size to 22 mm × 60 mm, and the alternative method is technically complicated. Melinex film is commercially available as 210 mm × 297 mm sheets and is approximately 1/20th the price of Thermanox and less than half the price of Aclar film. The method describes the preparation and use of embedding chambers made from Melinex film, glass slides and double-sided adhesive tape as a technically simpler, inexpensive and versatile alternative to both Thermanox coverslips and the Aclar film method.

Authors

Institutions

Publication Details

Journal
Journal of Microscopy
Published
2024-09-16
DOI
https://doi.org/10.1111/jmi.13359
Primary Topic
Dyeing and Modifying Textile Fibers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of Melinex film for flat embedding tissue sections in LR White

Christopher J. von Ruhland
Journal of Microscopy
Dyeing and Modifying Textile Fibers
article

Use of Melinex film for flat embedding tissue sections in LR White

Christopher J. von Ruhland
article en

Abstract

Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components, and this may necessitate removal of a considerable amount of material from the final resin-embedded tissue block to ensure production of complete sections of the sample. To mitigate this problem, a number of techniques have been devised that ensure the sample is held flat during the final curing/polymerisation of the resin. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin embedding are generally unsuitable. The method describes the preparation and use of air-tight flat-embedding chambers prepared from Melinex film and provides an inexpensive, technically simpler, and versatile alternative to chambers formed from either Thermanox coverslips or Aclar films that have previously been advocated for such purposes. Lay description: Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components. Such distortions may necessitate removal of a considerable amount of material to ensure production of complete sections of the sample. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin flat-embedding are generally unsuitable. Air-tight flat-embedding chambers prepared from either Thermanox coverslips, or a combination of PTFE-coated glass slides, polycarbonate film gaskets, and Aclar film have been advocated for such purposes. Thermanox coverslips are expensive and limited in size to 22 mm × 60 mm, and the alternative method is technically complicated. Melinex film is commercially available as 210 mm × 297 mm sheets and is approximately 1/20th the price of Thermanox and less than half the price of Aclar film. The method describes the preparation and use of embedding chambers made from Melinex film, glass slides and double-sided adhesive tape as a technically simpler, inexpensive and versatile alternative to both Thermanox coverslips and the Aclar film method.

Journal of MicroscopyVol. 297(1)
Cardiff University (GB)
Openalex Percentile: Top 84%
Dyeing and Modifying Textile Fibers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.